What To Do Before Calling For Service - Scotsman CU50PA-1 Installation And User Manual

Cube ice machine
Table of Contents

Advertisement

What to do before calling for service

Installation and User's Manual
10. Clean the bin liner of mineral scale by mixing
some ice machine scale remover and hot
water, and using that solution to scrub the
scale off of the liner.
11. Rinse the liner with hot water.
Sanitize the bin interior.
1. Mix a 1 gallon solution of locally approved
sanitizer.
Use an EPA approved food equipment sanitizer
at the solution mix recommended by the sanitizer
manufacturer.
2. Remove the top panel.
3. Pour 2 quarts of sanitizer solution onto the top
of the ice making platen. Be sure all surfaces
inside the platen are contacted by the sanitizer.
4. Return the top panel to its original position.
5. Remove the curtain, wash it with the sanitizing
solution. Return the curtain to its original
position.
6. Press and HOLD the both the Clean-Reset
and On/Off buttons for 5 seconds. The Time to
Clean light will blink on and off.
7. Thoroughly wash all surfaces of the reservoir,
bin liner, scoop, scoop holder and door liner
with the sanitizer solution. Pour excess solution
into bin to sanitize the drain.
8. Wait 10 minutes, push and release the On/Off
switch. The machine will begin to flush out the
sanitizing solution.
9. Operate the machine for another ½ hour.
10. Push and release the On/Off switch. The
machine will stop the cleaning process.
11. Push and release the On/Off switch again to
restart ice making.
Ice cubes are incompletely formed
• Clean the ice making system
Low capacity
• Check for restricted drain or standing water
in the bin
• Clean the air cooled condenser fins
No ice
• Check on-off switch
• Check electrical breaker
• If the Check Water light is flashing Red,
check water supply. The control system
checks for water every 20 minutes. When
the water supply is restored, the machine will
automatically restart ice making.
• If outdoors and the air temperature is below
50 degrees F., the machine may not operate.
Time to Clean light is on
• Clean the ice making system.
Erratic drain pump operation (pump models only)
• Clean and sanitize the bin. If the problem
continues contact a local service provider
July 2018