ALL INSTALLATIONS

Start here.
• Disconnect the electrical power supply and lock
out the service panel.
NOT FOR USE IN
A COOKING AREA.
IMPORTANT - The ducting from this fan to the outside
of the building has a strong effect on the air flow, noise and
energy use of the fan. Use the shortest, straightest duct routing
possible for best performance, and avoid installing the fan with
smaller ducts than recommended. Insulation around the ducts
can reduce energy loss and inhibit mold growth. Fans installed
with existing ducts may not achieve their rated airflow.
INSULATION
(Place around and
over fan housing.)
FAN
HOUSING
POWER
CABLE *
Seal gaps
around
housing.
4-IN. ROUND
DUCT *
Seal duct joints
* Purchase separately.
OPTION - To mount housing anywhere between ceiling
4
framing: Use optional Hanger Bar Kit (sold separately from local
distributors or website). Follow mounting instructions included
with kit.
WARNING
COOKING AREA
Do not install above or
inside this area.
o
o
45
45
Cooking
Equipment
ROOF CAP * (with built-in damper)
OR
with tape.
4-IN. ROUND
ELBOWS *
1. Remove blower and all
packing material from fan
housing.
Floor
2. Remove wiring panel from
fan housing.
Keep duct
runs short.
WALL CAP *
(with built-in
damper)