Intermittent Pilot Control System Troubleshooting (Fp7 Series) - Empire Comfort Systems DVD32 Installation Instructions And Owner's Manual

Direct-vent zero clearance gas fireplace heater
Table of Contents

Advertisement

INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING (FP7 SERIES)

Brief Description of the Components
The gas valve is fitted with a manual HI/LO knob to allow for man-
ual modulation of the gas outlet pressure to the appliance burner.
The controls are designed to be used with either Propane Gas or
Natural Gas and can be converted by use of an OEM supplied
conversion kit.
The Digital Fireplace Control (DFC) is an automatic gas ignition
system based on a single micro-controller core. This control man-
ages all functions related to ignition, flame sensing and supervi-
sion for atmospheric applications.
The DFC can be set to provide continuous or intermittent ignition
control sequences and flame monitoring with safety shutdown in
case of failure.
The DFC is set up as a stand alone (AC powered system with
battery back up. See Lighting Instructions on page 50 and Wiring
Diagram on page 49.
Troubleshooting
Before proceeding with the procedures in the following
troubleshooting table, verify that the power supply (AC/DC
adapter) is present and that the batteries inside the receiver and/or
optional battery pack are fresh and installed with correct polarity.
Make sure all the connections between the wire harnesses and
system components are proper and positive.
Verify that the static inlet pressure meets the manufacturer's
recommended inlet pressure. If necessary adjust the line pressure
regulator.
If the recommended actions for the following troubleshooting chart
do not help to address the problem consider replacing wiring
harnesses.
WARNING:
Any actions performed on the gas valve must be in accor-
dance with this instruction manual. Likewise, any actions
performed on the DFC or other system components must
be done in accordance with the individual component in-
structions.
Replacement of components must be performed in accor-
dance with this instructions manual.
31629-20-0320