Programming; Ul325 Entrapment Protection - Chamberlain LiftMaster HS670 Owner's Manual

Chamberlain liftmaster professional heavy duty hydraulic slide gate operator model hs670 operators manual
Hide thumbs Also See for LiftMaster HS670:
Table of Contents

Advertisement

UL325 ENTRAPMENT PROTECTION

PRIMARY ENTRAPMENT PROTECTION ADJUSTMENTS
Force Control
Set the force control pot such that the unit will complete a full
cycle of gate travel but can be reversed off an obstruction without
applying an unreasonable amount of force. On most operators
this will be around the middle of the range.
SECONDARY ENTRAPMENT PROTECTION ADJUSTMENTS
Terminals 9 & 5 - Obstruction While Opening
(Edge/Photo Eye Input)
Edge Input: See Programming Section on page 18.
This input will reverse an opening gate to the close limit.
Activating this input when the gate is closing will have no effect.
NOTE: If upon reversal a second separate obstruction is detected
(gate edge or RPM sensor), gate will stop and alarm.
Photo Eye Input: See Programming Section on page 18.
This input will pause an opening gate. Once the input (photo eye)
is cleared, the gate continues to open. Activating this input when
the gate is closing will have no effect.
Terminals 10 & 5 - Obstruction While Closing
(Edge/Photo Eye Input)
Edge Input: See Programming Section on page 18.
This input will reverse a closing gate to the open limit. When
reaching the open limit the timer to close, if enabled, will be
disabled until another command is given. Activating this input
when the gate is closing will have no effect.
NOTE: If upon reversal a second separate obstruction is detected
(gate edge or RPM sensor), gate will stop and alarm.
Photo Eye Input: See Programming Section on page 18.
This input will reverse a closing gate to the open limit. This input
will not affect the timer to close. Activating this input when the
gate is closing will have no effect.
Photo Eye Input: See Programming Section on page 18.
This input will reverse a closing gate to the open limit. This input
will not affect the timer to close. Activating this input when the
gate is closing will have no effect.
EDGE/PHOTO OPEN
This switch (S2-3) selects edge or photo sensor for the gate
opening protection input.
Open Photo Eye (Pause): When the
controller is configured for photo eyes,
the input functions to pause the gate
during the opening cycle. Once the
input is cleared the gate continues to
open.
Open Edge: When the controller is
configured for safety edges, the input
functions to reverse the gate to the
close limit when the edge is activated
during the opening cycle.
P R O G R A M M I N G
EDGE/PHOTO CLOSE
This switch (S2-4) selects edge or photo
sensor for the gate closing protection
input.
Close Photo Eye (Reverse): When the
controller is configured for photo eyes,
the input functions to reverse the gate to
PHOTO OPEN
the open limit when activated during the
S2
close cycle.
ON
Note: Timer to close will reset if enabled.
ON
Close Edge: When the controller is
1
2
3
4
configured for safety edges, the input
functions to reverse the gate to the open
EDGE OPEN
limit when activated during the close
cycle. The entrapment is not cleared at
S2
the limit and the timer to close will be
ON
disabled. The timer to close may be
enabled by activating the interrupt loop, open or override open
ON
1
2
3
4
inputs.
15
GL Controller Board
Edge Sensors
Transformer
Electrical Box
Edge Sensors
Force Control
Max.
Min.
Obstruction While Opening
(Edge/Photo Eye Input)
Obstruction While Closing
(Edge/Photo Eye Input)
PHOTO CLOSE
S2
ON
ON
1
2
3
EDGE CLOSE
S2
ON
ON
1
2
3
4
4