1. PREFACE

This service manual provides various service information, including the mechanical and electrical parts, etc.
This room air conditioner was manufactured and assembled under a strict quality control system.
The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit.

1.1 FEATURES

• DESIGNED FOR COOLING ONLY
• POWERFUL AND INCREDIBLE COOLING
• BUILT-IN ADJUSTABLE THERMOSTAT
• WASHABLE ONE-TOUCH FILTER
• COMPACT SIZE

1.2 SPECIFICATIONS

ITEMS
COOLING CAPACITY (BTU/h)
POWER SUPPLY (Phase, V, Hz)
INPUT (W)
OPERATING CURRENT (AMP.)
REFRIGERANT CONTROL
REFRIGERANT CHARGE (R-22)
INSIDE FAN
OUTSIDE FAN
AIR DISCHARGE
CHASSIS
PROTECTOR
TEMPERATURE CONTROL
ROTARY SWITCH
FAN MOTOR
• NOTE: Specifications are subject to minor change without notice for further improvement.
MODELS
PRO-FAN WITH SLINGER RING
2-WAY (RIGHT AND LEFT)
5 POSITIONS (LOW FAN, HIGH FAN, OFF, HIGH COOL, LOW COOL)
HQ-2051SH
5,250
1ø, 115V, 60HZ
540
5.0
CAPILLARY TUBE
220g (7.8 Oz)
TURBO
TOP-DOWN
• OVERLOAD PROTECTOR FOR COMPRESSOR
• INTERNAL PROTECTOR FOR FAN MOTOR
THERMOSTAT
6 POLES, 19.9W