Quick Reference Guide; Troubleshooting Information - Universal Security Instruments MICA3510S Manual

Table of Contents

Advertisement

C O N D I T I O N
New-Out of package .
DC power is present .
The Test button has been
pressed . The test sequence
lasts for approx 10 seconds .
Originating Smoke Alarm .
Originating CO alarm
Nuisance alarm
Smoke alarm when cause
of alarm is known and poses
no threat
CO alarm when cause of alarm
is known and poses no threat
Previous alarm condition at
unidentified source
Alarm needing reset due
to abnormal operation/
previous alarms
Low Battery or Product End-of-
Service Life Warning
Sensor Trouble Signal
RESET INSTRUCTIONS: Press the Test/Silence button for 10-15 seconds and then release . This will clear the alarm origination . Be sure to RESET
alarms after each alarm event . QUICK FIND® Alarm Origination/Location Feature: The QUICK FIND® feature will allow you to immediately locate
the originating alarm (the alarm that triggered the other alarms), once the alarms have stopped sounding.
1 . Press and release the Test/Silence button on alarm . After releasing the button, the test sequence on this alarm will begin, and
last approximately 5-20 seconds . If it is not the originating alarm, continue to each alarm until the originating alarm is located .
2 . Once this test sequence ends, the originating alarm continues to sound for approximately 60 seconds, which provides ample time to
locate the originating alarm .
3 . Remember to reset the originating alarm in order to clear the QUICK FIND® and return the system to normal operation .
NOTE: If you have any additional questions about the operation of Model MIC3510S, please contact our Customer Service Department
at 800-390-4321, and we will gladly assist you.
ALARM AUDIBLE & VISUAL SIGNALS
HORN
Silent
Silent
3 Beeps, 6
second pause,
4 beeps.
3 Beeps,
2 second
pause, repeat
4 Beeps, 5
second pause,
repeat
Horn sounds
when no hazard
present
3 Beeps,
2 second
pause, repeat
4 Beeps, 5
second pause,
repeat
Silent (alarmed
previously)
Silent (alarmed
previously)
2 Chirps approx
every 60
seconds
3 Chirps approx
every 60
seconds
THIS PRODUCT IS LISTED TO UL STANDARD FOR SAFETY, UL 217 and UL 2034
SMK RED
CO RED
LED
LED
Off
Off
Blinks On
Off
approx . every
2 minutes .
Blinks On in
Blinks On
sync with 3
in sync with
beeps .
4 beeps.
Blinks On in
Off
sync with the
3 beeps
Blinks on
Blinks On in
approx . every
sync with the
2 minutes
4 beeps
Blinks On in
Blinks On in
sync with the
sync with the
3 beeps
4 beeps
Blinks On in
Off
sync with the
3 beeps
Blinks on
Blinks On in
approx . every
sync with the
2 minutes
4 beeps
Blinks on
Off
approx . every
2 minutes
Blinks on
Off
approx . every
2 minutes
Blinks on
Off
approx . every
2 minutes
Blinks on
Off
approx . every
2 minutes
Page 13
RECOMMENDATION
To activate the alarm remove the pull tab .
The alarm will sound one long beep to confirm
it is powered up .
Alarm is operating properly .
None
If hazard is identified, please take all precau-
tions if an alarm sounds by calling Emergency
Service and getting out of the home .
If hazard is identified, please take all precau-
tions if an alarm sounds by calling Emergency
Service and getting out of the home .
If there is no hazard present, verify the alarm
is mounted in the correct location (see user's
manual). Reset alarm as instructed below.
The smoke alarm Silence Feature can be
activated by pressing and releasing the Silence
button while in alarm condition . Silence mode
will last for approximately 8 - 12 minutes [With
the red smoke LED blinking on approx every
10 seconds] .
The CO alarm Silence Feature can be
activated by pressing and releasing the Silence
button while in alarm condition . The alarm will
remain silent for approx 5 minutes [with the red
CO LED blinking on approx every 10 seconds],
depending on the level of CO detected . If CO
levels drop below alarm levels, the alarm will
remain silent and return to normal operation .
If CO levels remain constant or increase, this
indicates a potentially dangerous situation and
the horn will sound again . Ventilate area .
Quick Find® Alarm Origination - It may be dif-
ficult to determine which alarm has previously
sounded . The Quick Find® feature will allow
you to immediately locate the originating alarm
(once the alarm has stopped sounding). To
initiate Quick Find® press the Test/Silence
button on the alarm . After releasing the button
and following the test sequence, the originating
alarm will continue to sound for approximately
60 seconds .
To reset the alarm, hold the Test/Silence button
for 10-15 seconds . This will clear alarm origina-
tion . Reset after each alarm event .
Deactivate alarm (See User's Manual "ALARM
DEACTIVATION" section). Replace alarm
immediately .
Reset the alarm . If this does not clear the
problem, replace alarm .

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mic3510sbMic3510sMich3510s

Table of Contents