TO DEACTIVATE THE LOCKING FEATURES: To remove the smoke alarm for cleaning or servicing
or to replace the battery, you must first remove the appropriate locking pin, if it has been installed.
1.
Use long nose pliers to pull the locking pin out of the hole.
2.
It is now possible to remove the smoke alarm or replace the battery.
1.
Attach the mounting bracket to the wall or ceiling (your preference).
2.
To activate 9 volt battery and alarm, hold the QUICK DRAW
remove the PULL-TAB. Confirm that the entire PULL-TAB has been completely removed.
Discard PULL-TAB.
3.
Push and twist the alarm clockwise onto the mounting bracket.
4.
See "OPTIONAL TAMPER RESISTANT FEATURES" and "TO ACTIVATE THE LOCKING
FEATURES" instructions on Page 4.
5.
The red LED blinks on every 40-45 seconds to indicate proper operation.
OPERATION: The smoke alarm is operating once the battery power is connected by removing the
pull-tab. When products of combustion are sensed, the alarm sounds a loud alarm which continues
until the air is cleared.
This alarm incorporates the NFPA recognized horn signal for evacuation. During alarm mode, the
horn produces three long beeps followed by a two second pause and then continually repeats.
READY/ACTIVE CONDITION: The red LED blinks on once approx. every 40-45 seconds to indicate
the alarm is properly functioning.
ALARM CONDITION: The red LED blinks on once approx. every second and the alarm emits a
loud, pulsating alarm sound.
NUISANCE ALARMS: The smoke alarm is designed to minimize nuisance alarms. Smoking will
not normally set off the alarm unless smoke is blown directly into the smoke alarm. Combustion
particles from cooking may set off the alarm if the smoke alarm is located close to the kitchen
cooking surface. Large quantities of combustion particles are generated from spills or broiling.
If the smoke alarm does sound, check for fires first. If a fire is discovered, get out and call the fire
department. If no fire is present, check to see if one of the reasons listed above may have caused
the alarm. Use the Silence Feature if it is a nuisance alarm, or reset the alarm by pressing and
holding the test button for ten seconds. Refer to RESET below.
NOTE: It is best to "reset" the alarms before initial test is performed. See below for Reset instructions.
TESTING: Test by pushing the Test button on the smoke alarm cover until the alarm sounds, then
release. The alarm sounds if all electronic circuitry, horn and battery are working. If no alarm sounds,
the alarm may have a power supply failure. Test the smoke alarm weekly to assure proper operation.

RV INSTALLATION

WARNING: TEST SMOKE ALARM OPERATION AFTER VEHICLE HAS BEEN IN STORAGE,
BEFORE EACH TRIP AND AT LEAST ONCE PER WEEK DURING USE. An identical marking is to
be provided by the recreational vehicle manufacturer that shall be permanent and located visibly,
within 24 inches (810mm) of the smoke alarm.
ALARM ORIGINATION: The QUICK FIND
alarm (once the alarm has stopped sounding). To initiate QUICK FIND
button on each alarm. After releasing the button, the originating alarm will continue to sound for
approx. 60 seconds. In a non-interconnected installation, it is necessary to test each alarm to
determine the originating alarm.
RESET: To reset the QUICK FIND
approx. 10 seconds, or temporarily remove (and then replace) the battery. This will clear
alarm origination indicator.
END-OF-SERVICE LIFE NOTIFICATION: A majority of home fire deaths are a result of no smoke
alarms or no working smoke alarms. In addition to the "replace by date" stamped on the back of your
alarm, your alarm contains a unique audible end-of-service life notification feature. When it is time
to replace your alarm, which is approximately 10 years from the date of installation, the alarm will
sound 1 beep approximately every 35 seconds and the red LED blinks approximately 3 times. The
product end-of-service life can be temporarily silenced for a 24-hour period for up to 25 days. After
25 days, the warning cannot be silenced. The alarm should be replaced immediately.
MOUNTING INSTRUCTIONS
OPERATION, TESTING & MAINTENANCE
®
®
Alarm Origination Mode - Hold the Test/Silence button for
feature will allow you to immediately locate the originating
Page 5
(R)
battery drawer closed, pull and
®
, press the Test/Silence