Explosion Hazard - Wolf ICBCG15 Installation Instructions Manual

Table of Contents

Advertisement

W O L F
G A S S U P P LY
I M P O R T A N T
N O T E
This installation
IMPORTANT NOTE: The gas cooktop must
must conform with
local codes and
be connected to a regulated gas supply.
ordinances.
IMPORTANT NOTE: This installation must
conform with local codes and ordinances.
IMPORTANT NOTE: The natural gas cooktop
is rated for elevations up to 2438 m without
adjustment. Install a high altitude kit for
elevations from 2438 to 3084 m. The LP gas
cooktop is rated for 3084 m.
The rating plate, located on the underside of
the burner box, has information on the type
of gas that should be used. If this informa-
tion does not agree with the type of gas
available, check with the local gas supplier.
G A S
Refer to page 14
Appliance Commissioning
Apply the duplicate self adhesive data plate supplied
with the manual, to an adjacent cupboard door.
Adjusting Inlet Regulator - Adjust the inlet pressure
regulator until the test point pressure is 1 kPa for NG
and 2.75 kPa for Propane with 2 semi rapid burners
set at maximum rate.
10
G A S C O O K T O P S
R E Q U I R E M E N T S
EXPLOSION HAZARD —
Securely tighten all external gas
connections.
Failure to do so can result in explosion,
fire or death.
R AT I N G
Provide a gas supply line of 19 mm rigid
pipe to the cooktop location. A smaller
size pipe on long runs may result in
insufficient gas supply. Pipe joint
compounds, suitable for use with LP gas
should be used. For LP gas, piping or
tubing size can be 13 mm minimum. LP
gas suppliers usually determine the size
and materials used on the system.
If local codes permit, a flexible metal
appliance connector is recommended for
connecting this cooktop to the gas
supply line. Do not kink or damage the
flexible connector when moving the
cooktop. You will need to determine the
fittings required, depending on the size
of your gas supply line, flexible metal
connector and shut-off valve.
If rigid pipe is used as a gas supply line,
a combination of pipe fittings must be
used to obtain an in-line connection to
the cooktop. All strains must be removed
from the supply and gas lines so the
cooktop will be level and in line.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Icbcg304Icbcg365Icbcg365tsIcbcg152tfs

Table of Contents