Orifice, 1.40 mm
Orifice, 1.64 mm
Orifice, .68 mm
Label set
External natural gas regulator
TOOLS REQUIRED
3
/
" Socket
4
T-15 Torx bit
7 mm Socket
8 mm Socket
Clean gloves (pair)
Detergent solution (for leak testing)
These instructions describe reworking a Wolf
ICBCG152T/S or ICBCG152TF/S natural gas cooktop to
meet Australian specifications.
WARNING
To avoid serious burns and/or explosions, keep
combustibles away from the appliance whenever a flame
is present. Surfaces and components get hot during the
use of the appliance.
WARNING
Disconnect the product from the power source before
starting this procedure.
WARNING
Turn off the gas to the product at the supply source before
starting this procedure.
DISASSEMBLE THE UNIT
1
Remove the burner grate.
2
Remove both burner caps.
3
Remove both burner assemblies.
4
Remove the knobs.
5
Remove the bezels.
6
Remove the burner pan and glass panel.
REWORK THE UNIT TO AUSTRALIAN SPECIFICATIONS
1
For the front (9.2K) burner:
a)
Use an 8 mm socket to remove the main orifice
marked "158," along with its extension.
9029038 REV A
05/2019
ICBCG152T(F)/S Natural Gas Australia Rework
b)
2
For the rear (12K) burner:
a)
b)
c)
d)
Orifice extension
GAS LEAK TESTING
WARNING
Never test for a gas leak with a flame.
1
Brush a liquid detergent solution onto all gas
connections, then open the gas valve.
2
If bubbles appear, close the valve and adjust
connections.
3
Check for leaks again.
4
Clean off the detergent solution.
Page 1 of 2
wolfappliance.com
Use a 7 mm socket to install the 1.40 mm orifice
directly into the main orifice holder (without the
extension).
Use an 8 mm socket to remove the main orifice
marked "184," along with its extension.
Use a 7 mm socket to install the 1.64 mm orifice
directly into the main orifice holder (without the
extension).
Use a 7 mm socket to remove the simmer orifice
marked "65."
Use a 7 mm socket to install the 0.68 mm orifice
into the simmer orifice holder.
*9029038$REV$A*
800.222.7820

Advertisement

loading

Summary of Contents for Wolf ICBCG152T/S

  • Page 1 8 mm Socket Clean gloves (pair) Detergent solution (for leak testing) These instructions describe reworking a Wolf ICBCG152T/S or ICBCG152TF/S natural gas cooktop to meet Australian specifications. WARNING To avoid serious burns and/or explosions, keep combustibles away from the appliance whenever a flame is present.
  • Page 2 ICBCG152T(F)/S Natural Gas Australia Rework wolfappliance.com 800.222.7820 ATTACH THE LABELS UPDATE THE UNIT PACKAGE Attach the rating label (MF083) to the base of the Remove the old use and care guide and installation unit. guide from the unit package. Place a new use and care guide and installation guide in the unit package.