6.1.2 Additional installation site requirements of the outdoor unit in cold climates
Installer reference guide
28
Example: Behind the building.
a
If the outdoor unit is exposed to direct sea winds, install a windbreaker.
▪
Height of windbreaker≥1.5×height of outdoor unit
▪
Mind the service space requirements when installing the windbreaker.
a
d
c
a Sea wind
b Building
c Outdoor unit
d Windbreaker
The outdoor unit is designed for outdoor installation only, and for ambient
temperatures within the following ranges (unless otherwise specified in the
operation manual of the connected indoor unit):
Cooling mode
–10~46°C DB
Protect the outdoor unit against direct snowfall and take care that the outdoor unit
is NEVER snowed up.
c
a Snow cover or shed
b Pedestal
c Prevailing wind direction
b
c
d
c
b
a
c
b
Heating mode
–15~24°C DB
2(A)MXM40+50 + 2(A)MXF40+50
R32 Split series