USER GUIDE
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE •
LIMIT SWITCH SPECIFICATIONS
Normally closed Bi-metal switch
Open temperature: 104°F
Close temperature: 83°F
The function of this switch is to open in the event of an
overheating condition. This bi-metal thermostat is
normally closed and does not initiate the ice harvest
cycle. The ice harvest cycle is initiated by a double throw,
single pole temperature located remotely from the ice
maker assembly.
3.00
28.12
43
u-line.com
SERVICE
183-10
Troubleshooting - Extended 9