USER GUIDE
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE •
Harvest-2 Cycle
Ice maker ejector blades reach approximately 2:00
position and cam depresses the hold switch. Power goes
through the hold switch to the ice maker motor and mold
heater.
ON
OFF
black
SWITCH
black
LIMIT
SWITCH
black
(Hold Switch In Switched Position)
black
FAN
MOTOR
COMP.
OVER
START
LOAD
RELAY
WATER
C
FILL
NC
SWITCH
black
orange
black
MOLD HEATER
Ejector blades stall on ice and ice maker motor pulsates
until mold heater warms and ice releases.
HARVEST-2 CYCLE
black
brown
black
blue
ICE
orange
MAKER
MOTOR
black
40
ground
WATER
white
VALVE
HOLD
C
SWITCH
NC
NO
yellow
2
TEMP.
red NO
C
CONTROL
BIN
3
1
SWITCH
orange
Troubleshooting - Extended 6
u-line.com
SERVICE
UL183-6