Trane 2/4TEH3F18B1000A Installer's Manual page 10

Convertible air handlers

Advertisement

Installer's Guide
t
MANUFACTURED TRAPS
EZT-105
y
FIELD FABRICATED TRAP
CAP OR PLUG
2" MIN.
2" MIN.
Close as possible
Trap must be within 4'
of air handler condensate
drain connection.
WARNING
!
TO PREVENT INJURY OR DEATH DUE TO ELECTRICAL
SHOCK OR CONTACT WITH MOVING PARTS, LOCK
UNIT DISCONNECT SWITCH IN OPEN POSITION
BEFORE SERVICING UNIT.
H. ELECTRICAL — POWER WIRING
1. These Air Handlers are shipped from the factory
wired for 230 volts. The units may be wired for 208
volts. Follow instructions on unit wiring diagram lo-
10
2. The selection of wire and fuse sizes should be made
3. Field wiring diagrams for electric heaters and unit
2" MINIMUM
4. Wiring must conform to National and Local
2" MINIMUM
If an electric heater is not installed, the Knockout Plate
provided in the Accessory Kit MUST be installed on the
air handler and the conduit terminated to it. The elec-
trical connections are made using the two power leads
and ground wire connections which are located near the
discharge of the blower. Openings where field wir-
ing enters the cabinet must be completely sealed.
Location of power entry is shown on the outline draw-
ing. Use 2.5" clear stickers to seal all unused electrical
knockouts.
NOTE: If air handler is used with or without a heater,
the 7/8" electrical entry hole as well as any other
cabinet penetrations must be sealed air tight.
I. CONTROL WIRING
1. Connect wiring between indoor unit, outdoor unit
2. Field wiring diagrams are provided which show the
IMPORTANT:
When supplementary heaters are installed, inspect to in-
sure that all packaging material has been removed.
NOTE: Direct drive motors have bearings which are
permanently lubricated and under normal use lubri-
cation is not recommended.
cated on blower housing and in the Service Facts
document included with the unit.
according to the Minimum Branch Circuit Ampacity
and the Maximum Overcurrent Device listed on the
unit nameplate.
accessories are shipped with the accessory.
codes. Ground unit per Local codes with good
safety procedures.
and Comfort Control. The use of color-coded low-
voltage wires is recommended.
low voltage wiring hook-up for a single speed
cooling only system (with supplementary heaters)
and a heat pump system (with supplementary
heaters). Plug in type electrical connectors are
provided for use with supplementary heaters.
HOOK-UP DIAGRAMS