8-16. Poor cooling in Fresh food section
Symptom
1. Poor cooling in Fresh
food section
CON1
CON201
1. Check the sensor resistance
2. Check the air flow
3. Check the air Temperature
4. Check the R-Damper motor voltage
CON2 CON3
F-Fan motor
R-Sensor
Check Point
CON5
CON6
CON7
th
th
CON7 15
pin ~ 18
pin
23ºF / -5ºC
32ºF / 0ºC
41ºF / 5ºC
50ºF / 10ºC
59ºF / 15ºC
TEST MODE 1
th
th
CON7 12
pin ~ 14
pin
th
th
CON7 16
pin ~ 14
pin
th
th
CON7 10
pin ~ 14
pin
Duct
Status
Air Flow
Windy
Air Temperature
Duct
Fan Motor
Resistance [Ω]
38k
30k
24k
19.5k
16k
Voltage [V]
12V
0V<Voltage<5V
0V<Voltage<5V