Maintenance and annual startup
Table 2A Service and Maintenance Schedules
Service technician
(see the following pages for instructions)
General:
• Address reported problems
• Inspect interior; clean and vacuum if
necessary
Check for leaks (water, gas, and flue)
• Verify flue and air lines in good
condition and sealed tight
• Check control settings per the Access
Setup Menu section of this manual
• Check ignition and flame sense
electrodes (sand off any deposits;
clean and reposition)
• Check wiring and connections
• Perform
performance verification per Section 9
in the EnergyRite Installation and
Operation Manual
• Flame inspection (stable, uniform)
If combustion or performance
indicate need:
• Clean burners
• Clean heat exchanger
start-up
checkout
and
Owner maintenance
(see the EnergyRite User's Information Manual for
instructions)
Daily
• Check pool heater area
• Check vent piping
• Check
Monthly
applicable)
• Check relief valve (if applicable)
• Test low water cutoff (if used)
Periodically
• Reset button (low water cutoff)
• Check pool heater piping (gas
and water) for leaks
Every
6 months
• Operate
applicable)
• Shut the pool heater down and
End
winterize if location is subjected
of season
to freezing temperatures, see the
Winterizing section on page 21 of
this manual