3. Specifications
Model
Performance Test Condition
Power Supply
Capacity
Running Current
Input Power
Annual Consumption
EER CLASS
EER
ErP
Annual Consumption
Power Factor
Indoor Noise (H / L / QLo)
Outdoor Noise (H / L / QLo)
Capacity
Running Current
Input Power
COP CLASS
COP
Tbivalent
ErP
Annual Consumption
Power Factor
Indoor Noise (H / L / QLo)
Outdoor Noise (H / L / QLo)
LOW Temp: Capacity (kW) / I. Power (W) / COP
EXTR LOW Temp: Capacity (kW) / I. Power (W) / COP
Max Current (A) / Max Input Power (W)
Indoor
Outdoor
Phase, Hz
BTU/hW
kcal/hW
Pdesign
SEER
Class
Sound Pressure Level
Sound Power Level dB(A)
Sound Pressure Level
Sound Power Level dB(A)
BTU/hW
kcal/hW
Pdesign
SCOP
Class
Sound Pressure Level
Sound Power Level dB(A)
Sound Pressure Level
Sound Power Level dB(A)
V
Min.
kW
0.75
BTU/h
2560
kcal/h
650
A
-
W
160
kWh
-
-
W/W
4.69
16.00
4.06
kW
(W/W)
kWh
%
-
dB(A)
dB(A)
kW
0.75
BTU/h
2560
kcal/h
650
A
-
W
160
-
W/W
4.69
16.00
4.06
kW
°C
(W/W)
kWh
%
-
dB(A)
dB(A)
12
CS-XZ20XKEW-H
CU-Z20XKE
EUROVENT
Single, 50
230
Mid.
2.05
6990
1760
2.15
450
225
A
4.56
15.53
3.91
2.1
8.1
91
A++
91
37 / 24 / 19 (Single)
39 / 26 / - (Multi)
53 / - / -
45 / - / -
60 / - / -
2.80
9550
2410
2.80
620
A
4.52
15.40
3.89
2.1
-10
4.8
613
A++
96
38 / 25 / 19 (Single)
40 / 27 / - (Multi)
54 / - / -
46 / - / -
61 / - / -
2.90 / 830 / 3.49
2.38 / 840 / 2.83
4.1 / 940
Max.
2.65
9040
2280
-
670
-
-
3.96
13.49
3.40
-
4.00
13600
3440
-
940
-
4.26
14.47
3.66
-