Function Description - Devolo MT 02648 Manual

Door/window contact and the motion detector
Table of Contents

Advertisement

second.
Notice: Including a node ID allocated by Z-Wave
"Add" or "Inclusion". Excluding a node ID allocated by Z-Wave
Controller means "Remove" or "Exclusion".
Description
Function
1. Have Z-Wave
2. Pressing tamper key three times within 1.5 seconds
to enter the inclusion mode.
Add
3. After inclusion successful, the device will wake to
receive the setting command from Z-Wave
Controller about 20 seconds.
1. Have Z-Wave
2. Pressing tamper key three times within 1.5 seconds
Remove
to enter the exclusion mode.
Node ID has been excluded.
Notice: Use this procedure only in the event
that the primary controller is lost or
otherwise inoperable.
1. Pressing tamper key four times within 1.5 seconds
and do not release the tamper key in the 4
pressed, and the LED will light ON.
Reset
2. After 3 seconds the LED will turn OFF, after that
within 2 seconds, release the tamper key. If
successful, the LED will light ON one second.
Otherwise, the LED will flash once.
3. IDs are excluded and all settings will reset to
factory default.
Association 1. Have Z-Wave
mode.
2. Pressing tamper key three times within 1.5 seconds
to enter the association mode.
TM
Controller means
TM
Controller entered inclusion mode.
TM
Controller entered exclusion mode.
TM
Controller entered association
TM
Failed or success in including/excluding the node ID can be
viewed from Z-Wave
Notice 1: Always RESET a Z-Wave
Z-Wave
TM
network
TM
Notice 2: When the device into NWI mode, the sensor functionality
will useless. The NWI mode will timeout after 30 seconds. You can
press the tamper key 3 times to abort the NWI mode.
Z-Wave
TM
After the device adding to the network, it will wake-up once per day in
default. When it wake-up it will broadcast the "Wake Up Notification"
message to the network, and wake-up 10 seconds for receive the
setting commands.
The wake-up interval minimum setting is 30 minutes, and maximum
th
setting is 120 hours. And the interval step is 30 minutes.
If the user want to wake-up the device immediately, please remove the
front cover, and press the tamper key once. The device will wake-up 10
seconds.
Z-Wave
TM
When the Motion Detector triggered or the Door/Window Contact
triggered, the device will report the trigger event and also report the
battery status, temperature and illumination level.
2
Note: The device support 2 groups. The group 1 is for
receiving the report message, like triggered event,
temperature, illumination etc. The group 2 is for light
control, the device will send the "Basic Set" command
to this group. And each group support 8 nodes
maximum.
TM
Controller.
TM
device before trying to add it to a
Notification
Message Report

Advertisement

Table of Contents
loading

Table of Contents