13. LIST OF ERROR CODES
P.C. board-related errors
Code
Abnormal rise in power supply voltage was
E700
detected when power was turned on.
Abnormal rise in sewing machine motor power
E701
supply voltage was detected.
Abnormal drop in power supply voltage was
E705
detected.
Power supply signal could not be detected when
E709
power was turned on.
Abnormal sewing machine motor current was
E710
detected.
Abnormal electrical current for feed motor is
E711
detected.
Abnormal solenoid mechanism current detected
E791
when solenoid was activated.
Version updating errors
Code
Version update request could not be received when
E880
power was turned on.
Communication error was detected during main
E881
version update.
No USB medial connected when power was turned
E882
on.
Version update file could not be detected in USB
E883
media when power was turned on.
Problem with version update file detected during
E884
version updating.
Version update file could not be read from USB
E885
media during version updating.
Problem with version update file detected during
E886
version updating.
Version update file could not be written during
E887
version updating.
Error sending or receiving version update file.
E888
Incorrect data written to flash memory.
E889
Error occurred during version update.
E890
If an error code that is not listed above appears or if carrying out the specified remedy does not solve the problem,
contact the place of purchase.
89
Cause
Cause
S-7300A
Remedy
Turn off the power and check the power supply
voltage.
・Turn off the power and check the power supply
voltage.
・Turn off the power and check the connection of
connector P13.
Turn off the power and check the power supply
voltage.
Turn the power off and then back on again.
Turn off the power and check the connection of
connector P5.
Turn off the power and check the connection of
connector P4.
Turn off the power and check the connection of
connector P1.
Remedy
Turn off the power and check the connection of
connector P2.
Turn off the power and check the connection of
connector P2.
Turn off the power and check the connection of the
USB media.
Turn off the power and then check that the version
update file is contained in the USB media.
Turn off the power, and then repeat the version
update procedure.
Turn off the power and check the connection of the
USB media.
Turn off the power, and then repeat the version
update procedure.
Turn off the power, and then repeat the version
update procedure.
Turn off the power, and then repeat the version
update procedure.
Turn off the power, and then repeat the version
update procedure.
Turn off the power, and then repeat the version
update procedure.