2.11 LOW OIL LEVEL SHUTDOWN SYSTEM

The engine is equipped with a low oil level sensor that shuts down
the engine automatically when the oil level drops below a specified
level. If the engine shuts down by itself and the fuel tank has enough
gasoline, check engine oil level.
2.11.1 SENSING LOW OIL LEVEL
If the system senses a low oil level during operation, the engine shuts
down. The engine will not run until the oil has been refilled to the
proper level.
2.12 CHARGING THE BATTERY (ELECTRIC
START UNITS ONLY)

 Storage batteries give off explosive hydrogen gas while
recharging. An explosive mixture will remain around the
battery for a long time after it has been charged. The
slightest spark can ignite the hydrogen and cause an
explosion. Such an explosion can shatter the battery and
cause blindness or other serious injury.
n
Do not permit smoking, open flame, sparks or any other
source of heat around a battery. Wear protective goggles,
rubber apron and rubber gloves when working around a
battery. Battery electrolyte fluid is an extremely corrosive
sulfuric acid solution that can cause severe burns. If spill
occurs flush area with clear water immediately.
The battery shipped with the generator has been fully charged.
A battery may lose some of its charge when not in use for
prolonged periods of time. If the battery is unable to crank the
engine, plug in the 12V charger included in the accessory box.
RUNNING THE GENERATOR DOES NOT CHARGE THE BATTERY.
Use battery charger plug to keep the battery charged and ready for
use. Battery charging should be done in a dry location.
1. Plug charger into "Battery Charger Input" jack, located on the
control panel (Figure 12). Plug wall receptacle end of the battery
charger into a 120 Volt AC wall outlet.
2. Unplug battery charger from wall outlet and control panel jack
when generator is going to be in use.
Charge the battery at least once every three (3) months. Do not
use the battery charger for more than 48 hours at one charge.
Charger input is protected by a 1.5 Amp replaceable in-line fuse.
NOTE:
NOTE:
Figure 12 - Battery Charger Jack
BATTERY
CHARGER
3.1

PERFORMING SCHEDULED MAINTENANCE

It is important to perform service as specified in the Maintenance
Schedule for proper generator operation, and to ensure that the
generator complies with the applicable emission standards for the
duration of its useful life. Service and repairs may be performed by
any capable person or repair shop. Additionally, emissions critical
maintenance must be performed as scheduled in order for the
Emissions Warranty to be valid. Emissions critical maintenance
consists of servicing the air filter and spark plugs in accordance with
the Maintenance Schedule.
3.2

MAINTENANCE SCHEDULE

Follow the calendar intervals. More frequent service is required when
operating in adverse conditions noted below.
Check Oil Level
Change Oil ‡
Check Valve Clearance
Service Air Filter
Replace Spark Plug
‡ Change oil after first 30 hours of operation then every season.
*
Change oil and oil filter every month when operating under heavy load or in high
temperatures.
** Clean more often under dirty or dusty operating conditions. Replace air filter parts
if they cannot be adequately cleaned.
*** Check valve clearance and adjust if necessary after first 50 hours of operation and
every 100 hours thereafter.
3.3

PRODUCT SPECIFICATIONS

3.3.1 GENERATOR SPECIFICATIONS
Rated Power ..................................................................................... 8.0 kW**
Surge Power ......................................................................................... 10 kW
Rated AC Voltage .............................................................................. 120/240
Rated AC Load
Current @ 240V ....................................................................... 33.3 Amps**
Current @ 120V ....................................................................... 66.6 Amps**
Rated Frequency ............................................................ 60 Hz @ 3600 RPM
Phase ........................................................................................ Single Phase
Unit Weight .............................................................................. 86.9kg (191.5)
Unit Dimensions ............................L = 692mm (27.25") x W = 687mm (27") x
** Operating Temperature Range : -18 deg. C (0 deg. F) to 40 Deg. C (104 Deg. F).
When operated above 25 deg. C (77 deg. F) there may be a decrease in power.
** Maximum wattage and current are subject to, and limited by, such factors as fuel
Btu content, ambient temperature, altitude, engine condition, etc.. Maximum power
decreases about 3.5% for each 1,000 feet above sea level; and will also decrease
about 1% for each 6° C (10° F) above 16° C (60° F) ambient temperature.

Maintenance

INPUT
At Each Use
*Every 100 hours or Every Season
***Every Season
** Every 200 hours or Every Season
Every Season