Assembly Of Backguard/High Shelf; Code Requirements; Electrical Supply; Single And Three Phase Connection - Garland SS680 Series Installation And Operation Manual

Restaurant ranges and salamanders
Table of Contents

Advertisement

INSTALLATION Continued
NOTE: When mounting a salamander over an existing range
in the field, an independent fussed connection must be
made though the knock out plate provided in the main back
of the salamander.

Assembly of Backguard/High Shelf

The back guard or high shelf will have been shipped
separately. To install, put the backguard/high self on the rear
of the range, slipping the uprights into the opening on each
burner box side. Fasten the upright to the burner box side
with four hex fasteners provided.

Code Requirements

The Garland S/SS680 series complies with the standards CSA
C22.2 no.109 – latest edition, the UL197 – latest edition and
the NSF#4 – latest edition. The installation and connection
of this appliance must comply with current codes. In Canada
– The Canadian Electrical Code Part 1 and in the USA – The
National Electrical Code.
The Garland SU680 series complies with the essential
requirements of the Directives 73/23/EEC, 89/336/EEC,
89/392/EEC, 93/68/EEC and the standards, EN60335,
IEC801.2, IEC801.3, IEC801.4, IEC801.5, IEC801.6 and
IEC801.11.

Electrical Supply

Before attempting the electrical connection, the rating plate
should be checked to ensure that the equipment's electrical
characteristics and supply electrical characteristics agree. On
ranges and salamanders the supply entrance is located at the
rear or alternatively on the main bottom. The supply terminal
block is accessible from the front. The electrical supply must
be adequate for the voltage, phase, and current marked on
the rating plate.
Page 10
NOTE: A means of disconnection from the supply having
a contact separation of at least 3 mm in all poles must be
incorporated in the fixed wiring.
This equipment is intended to be installed with fixed
permanent wiring.
WARNING: This appliance must be grounded.

Single And Three Phase Connection

Unless otherwise noted, all ranges are shipped from the
factory for three phase connection. Salamanders are shipped
from the factory for single phase connection. A wiring
diagram is attached to the rear of each appliance. Visually
check all electrical connections. The range is wired at the
factory as specified on the order. If it is necessary to change
the phasing refer to the wiring diagram.

Commissioning

Ensure all circuit breakers located in the lower compartment
are set to the ON (1) position
1. Ensure that all controls are in the OFF position and turn
on the main electrical supply.
2. Operate each section of the range or salamander in
accordance with the instructions given in the Operating
Instructions.
3. Check that the product functions correctly and that the
voltage supply to the unit does not drop more than 5%
when all sections are operated simultaneously.
Part # 4527853 Rev. 2 (10/18/11)