General I/O Terminal Block - Vivotek IP3111/3121 User Manual

Vivotek user's manual network camera ip3111/3121
Table of Contents

Advertisement

General I/O terminal block

1
DI+
2
DI-
3
SW_COMMON OUTPUT
4
SW_NOPEN
5
RS485 B
6
RS485 A
Network Camera provides a very flexible general I/O interface to combine with the user's security
devices such as sensors, alarms, lighting or door locks. The general I/O terminal block has six pins for
device control. These pins can be divided into two categories based on their functions, including RS485
and digital inputs and outputs.
If the device connected to COM has an RS485 interface, wire two control lines to pin 5 and pin 6. After
switching to RS485 on the configuration page, the PT control commands will be directed through pin 5
and pin 6. If the distance from the controlled device is too far to allow accurate function, an external
power source may be used to pull high the RS485 signal.
Network Camera provides one digital input and one relay switch. Pin 1 and pin 2 can be connected to
external sensor and the state of voltage will be monitored according to the programmed scripts in
configuration. The relay switch can be used to turn on or off external devices.
INPUT
(Max. 50mA, 12VDC)
INPUT
(short with NC at initial state)
OUTPUT
(Max. 1A, 24VDC or 0.5A, 125VAC)
(inverting)
(non-inverting)
9
www.vivotek.com
T: 886-2-22404099
F: 886-2-22404097

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ip3111Ip3121

Table of Contents