M AC H I N E ASS E M B LY

Safety Interlock

The interlock is supplied only for those countries requiring this feature.
With the machine plugged into the nearest outlet, the magnetic safety lock
will disengage the power supply to the motor when the safety lid is lifted into
an upright position while placing the container on the centering pad (Figure A).
Power is engaged whenever the safety lid is lowered onto the container lid
(Figure B). The accelerator tool can be used through the safety lid and
container lid while blending.
FIGURE A
Safety Interlock lid in the open position.
Machine power disengaged.
WARNINGS!
Do not run the machine without the container lid when using the interlock.
14
FIGURE B
Safety Interlock lid in the closed position.
Machine power is engaged.

Blade Assembly

Blade Agitator Assembly: The blade assembly
includes a precision-hardened stainless steel blade
with enclosed double sealed steel ball bearings for
maximum durability. The rugged blade assembly
literally explodes molecules of food and ice in the
container, helping every batch to homogenize
more effectively. The blades do not need to
be removed for normal cleaning. (Refer to the
information below to remove or replace.)
Drive Spline: Inserts into drive socket on the motor
base to turn the blade.
Note: Removing and replacing your container
while the coupling is still rotating will strip the
drive spline "teeth." (This part is NOT removable.)
Retainer Nut: Must be snug. Order the available
Retainer Nut Wrench for best results. (Refer to
the information below to remove or replace.)
Blade Assembly Removal
Retainer Nut Wrench
At times, it may be necessary to give your blades
additional cleaning. An easy-to-use blade assembly
removal wrench (Item #15596) may be purchased.
Turn the container upside down and grip firmly.
Insert retainer nut wrench in groove of retainer nut
and rotate counterclockwise to loosen. Then grip
blades with a cloth and remove retainer nut by hand.
Replacing Blade Assembly: With the container
upside down, grip blades with cloth, insert into
the container bottom and align with flat sides of
container opening. Place retainer nut on and hand
tighten. Using the retainer nut wrench, carefully
turn clockwise until secure, using wrench.
Retainer Nut Wrench in use
Do not force. If it is not tight enough, you will
notice increased container noise.
WARNINGS!
Never use a blade assembly with loose, damaged or nicked components.
Caution: Do not remove blades or blade assembly unless absolutely necessary!
Never attempt to take the blade assembly itself apart. This will void the warranty.