Installation
Electrical Connection (4-wire) Dual Fuel Ranges
1
Remove access door.
3
Remove grounding screw. Cut-off
and discard ground strap.
5
Attach ground lead (green)
with ground screw that was removed.
2
Remove supply cord strain relief
bracket and three supply cord mounting screws on
the terminal block.
4
Feed supply cord up through hole in bottom
of range back.
6
Attach line #1 (red) and line #2 (black)
leads to outside terminals. Attach neutral wire (white)
to center terminal on terminal block.