Quick Reference Guide - Honeywell G0070632 Owner's Manual

60 hz air-cooled generators 9 kw to 22 kw
Table of Contents

Advertisement

Quick Reference Guide

To clear an active alarm, press the OFF mode button on the control panel, then the ENTER button, and finally the
AUTO mode button. Contact an IASD if the alarm reoccurs.
Active Alarm
LED
FLASHING
NONE
GREEN
HIGH
RED
TEMPERATURE
OVERLOAD
RED
REMOVE LOAD
RPM SENSE LOSS RED
NOT ACTIVATED
NONE
NONE
GREEN
LOW OIL
RED
PRESSURE
RPM SENSE LOSS RED
OVERCRANK
RED
LOW VOLTS
RED
REMOVE LOAD
OVERSPEED
RED
UNDERVOLTAGE
RED
UNDERSPEED
RED
STEPPER
RED
OVERCURRENT
MISWIRE
RED
Owner's Manual for 60 Hz Air-Cooled Generators
Problem
Things to Check
Unit running in AUTO
Check MLCB.
but no power in house.
Unit shuts down during
Check the LEDs /
operation.
screen for alarms.
Unit shuts down during
Check the LEDs /
operation.
screen for alarms.
Unit was running and
Check the LEDs /
shut down, attempts to
screen for alarms.
restart.
Unit will not start in
Check if screen says
AUTO with utility loss.
unit not activated.
Unit will not start in
Check screen for start
AUTO with utility loss.
delay countdown.
Unit will not start in
Check the LEDs /
AUTO with utility loss.
screen for alarms.
Unit will not start in
Check the LEDs /
AUTO with utility loss.
screen for alarms.
Unit will not start in
Check the LEDs /
AUTO with utility loss.
screen for alarms.
Unit will not start in
Check the LEDs /
AUTO with utility loss.
screen for alarms.
Unit will not start in
Check the LEDs /
AUTO with utility loss.
screen for alarms.
Unit will not start in
Check the LEDs /
AUTO with utility loss.
screen for alarms.
Unit will not start in
Check the LEDs /
AUTO with utility loss.
screen for alarms.
Unit will not start in
Check the LEDs /
AUTO with utility loss.
screen for alarms.
Unit will not start in
Check the LEDs /
AUTO with utility loss.
screen for alarms.
Troubleshooting / Quick Reference Guide
Solution
Check MLCB. If it is ON, contact an IASD.
Check ventilation around the generator,
intake, exhaust, and rear of generator. If
no obstructions are present, contact an
IASD.
Clear alarm and remove household loads
from the generator. Put in AUTO and
restart.
Clear alarm and remove household loads
from the generator. Put into AUTO and
restart. If generator does not start, contact
an IASD.
Refer to "Activation" in installation
manual.
If the startup delay is greater than
expected, contact an IASD to adjust from
2 to 1500 seconds.
Check oil level and add oil as needed. If
oil level is correct, contact an IASD.
Clear alarm. Using the control panel,
check the battery by navigating to the
BATTERY MENU option from the MAIN
MENU. If battery condition displays
GOOD, contact an IASD. If control panel
displays CHECK BATTERY, replace the
battery.
Check fuel line shutoff valve is ON. Clear
alarm. Start the unit in MANUAL. If it does
not start, or starts and runs rough, contact
an IASD.
Clear alarm and remove household loads
from the generator. Put in AUTO and
restart.
Contact an IASD.
Contact an IASD.
Contact an IASD.
Contact an IASD.
Contact an IASD.
37