Setting The Exercise Timer; Battery Charger - Honeywell G0070632 Owner's Manual

60 hz air-cooled generators 9 kw to 22 kw
Table of Contents

Advertisement

Operation

Setting the Exercise Timer

This generator is equipped with a configurable exercise
timer. Configuration can be performed directly at the control
panel or though the Mobile Link™ application. There are two
settings for the exercise timer:
Day/Time: The generator will start and exercise for the
period defined, on the day of the week and at the time of day
specified. During this exercise period, the unit runs for
approximately five minutes and then shuts down.
NOTE: If Wi-Fi is enabled, the exercise timer will
automatically adjust for Daylight Savings Time.
Exercise frequency: Exercise frequency can be set to
Weekly, Biweekly, or Monthly. If Monthly is selected, the day
of the month must be selected from 1-28. The generator will
exercise on that day each month. Transfer of loads to the
generator output does not occur during the exercise cycle
unless utility power is lost.
NOTE: The exercise feature will operate only when the
generator is in AUTO mode, and will not work unless this
procedure is performed. If Wi-Fi is NOT enabled, the current
date/time will need to be reset every time the 12 volt battery
is disconnected and then reconnected, and/or when the fuse
is removed.
Figure 3-10
illustrates an engine speed profile during a
typical
exercise
cycle.
information and programming options for all home standby
generators.
Low Speed Exercise Profile—9–22 kW Generators
3800
3600
3400
3200
3000
2800
2600
2400
2200
2000
1800
0 sec
5 s
10 s
15 s
20 s
Figure 3-10. Low Speed Exercise Profile
NOTE: If Quiet Test is disabled, the generator will
exercise at the rated rpm.
Table 3-1. Generator Exercise Characteristics
Generator Size
Low Speed Exercise
Exercise Frequency
Options
Exercise Time Length
20
Table 3-1
details
exercise
25 s
30 s
35 s
40 s
45 s
1 min
Exercise Time
9–22 kW
1950 rpm
Weekly/Bi-Weekly/Monthly
5 minutes

Battery Charger

IMPORTANT NOTE: Contact an IASD if the controller
screen displays "CHARGER MISSING AC."
NOTE: The battery charger is integrated into the control
module in all models.
The battery charger operates as a smart charger which verifies:
output
is
maximum battery life.
charging levels are safe.
NOTE: A warning is displayed on the LCD when the
battery needs service.
NOTE: Do not use external battery chargers.
5 min
004448
Owner's Manual for 60 Hz Air-Cooled Generators
continually
optimized
to
promote

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents