Tripp Lite SmartOnline SU10KRT1X Owner's Manual
Tripp Lite SmartOnline SU10KRT1X Owner's Manual

Tripp Lite SmartOnline SU10KRT1X Owner's Manual

Rack/tower on-line ups system with parallel redundancy capability

Advertisement

SmartOnline
Output: User-Selectable 200/220/230/240V AC, 50/60 Hz, 1Ø, 2-Wire + Ground
Copyright © 2009 Tripp Lite. SmartOnline is a trademark of Tripp Lite. All other trademarks are the sole property of their respective owners.
Owner's Manual
SU10KRT3/1X
Rack/Tower On-Line UPS System
with Parallel Redundancy Capability
Input: 160-280/277-485V AC, 50/60 Hz, 3Ø, 4-Wire + Ground, Wye
Not suitable for mobile applications.
1111 W. 35th Street, Chicago, IL 60609 USA
+1.773.869.1234 • www.tripplite.com
2
2
4
5
5
6
6
7
8
8
8
8
9
10
11
Español
11
Français
12
Русский
1
13
14
14
14
16
17
17
17
17
18
19
19
20
21
22
43
64

Advertisement

Table of Contents
loading

Summary of Contents for Tripp Lite SmartOnline SU10KRT1X

  • Page 1: Table Of Contents

    6 – Standard Operation 6-1 Control Panel Features 6-2 Control Panel Error Codes Copyright © 2009 Tripp Lite. SmartOnline is a trademark of Tripp Lite. All other trademarks are the sole property of their respective owners. SU10KRT3/1X Rack/Tower On-Line UPS System ™...
  • Page 2: Introduction

    1 – Introduction Tripp Lite’s SmartOnline Rack/Tower On-Line UPS System with Parallel Redundancy Capability provides long-lasting battery backup for data centers, telecommunications, networks, industrial facilities, security, emergency systems and other critical applications that require high capacity, high availability and extended runtime. True on-line operation continuously transforms 3-phase input power into precision-regulated single-phase output to guarantee maximum equipment protection and stability.
  • Page 3: Wiring Warnings

    • The batteries are recyclable. Refer to local codes for disposal requirements. Do not dispose of batteries except through approved channels in accordance with all applicable local, state and national regulations. • Tripp Lite offers a complete line of UPS system Replacement Battery Cartridges (R.B.C.). Contact Tripp Lite to determine the specific replacement battery for the UPS system.
  • Page 4: Rear Panel Features

    3 – Rear Panel Features Note: Refer to Section 6-1 for a description of the UPS system’s control panel. UPS System Power Module Rear Panel RS-232 Port (Note: Remove the network card in order to use the RS-232 port.) Settings Switch for Parallel Redundancy Operation CAN Bus Connection Ports for Parallel Redundancy Operation Cooling Fans External Battery Pack DC Cable Connector...
  • Page 5: Mounting

    4 – Mounting Read Section 2 – Important Safety Instructions Before Mounting Warning: The UPS system is very heavy—be careful when moving or lifting it. 4-1 Unpacking Remove the protective foam and unwrap the unit. Inspect the unit carefully prior to installation. If anything appears to be damaged, contact Tripp Lite for service.
  • Page 6: Placement

    • Use the included rackmount shelves and mounting hardware to mount the UPS system in a 4-post rack or rack enclosure. To mount the UPS system in a 2-post (telecom) rack, order Tripp Lite’s 2-Post Rackmount Kit (model 2POSTRMKITWM, sold separately).
  • Page 7: Mounting (Tower)

    4 – Mounting continued 4-4 Mounting (Tower) Warning: When mounting the UPS system in a tower position, make sure the control panel is closer to the top of the cabinet than the bottom. Note: The control panel can be rotated to match the UPS system’s position. Pull the panel out slightly, rotate it and push it back into place. Tower Mounting Procedure Use M4 flat-head screws to attach covers...
  • Page 8: Wiring

    5 – Wiring DANGER! LETHAL HIGH VOLTAGE HAZARD! All wiring should be performed by a qualified electrician, in accordance with the warnings in this manual and all applicable electrical and safety codes. Incorrect wiring may cause serious personal injury and property damage. Read, study and understand the warnings listed in Section 2 –...
  • Page 9: Ac Input/Output Wiring Instructions

    5 – Wiring continued 5-4 AC Input/Output Wiring Instructions Use M3 pan-head screws to attach the cable attachment tray Route the AC input/output wiring through cable sleeves and route the cable sleeves through the knockouts in the terminal block cover Each input/output wire should terminate with a ring terminal.
  • Page 10: External Battery Pack Connection

    Additional external battery packs, sold separately, may be connected to the UPS system for additional battery backup runtime. Contact Tripp Lite customer service to order additional external battery packs. Switch the external battery pack’s DC breaker to the ON position.
  • Page 11: Standard Operation

    Bypass LED: If an internal fault or overload occurs, the LED will flash repeatedly to show that connected equipment will receive filtered AC line power, but will not receive battery power during a blackout. In this case, contact Tripp Lite for service.
  • Page 12: Control Panel Error Codes

    6 – Standard Operation 6-1 Control Panel Features LCD Symbols Symbol Description LINE Utility or Bypass Source Battery Low Battery Abnormal/Fault UPS Overload UPS Operating in Specified Mode (Normal, Economy, etc.) A Transfer to Battery Occurred in the UPS Output UPS Failure to Transfer to Bypass or Bypass Abnormal in ECO Mode Utility Input Abnormal UPS Shutoff...
  • Page 13: Normal Mode Startup

    6 – Standard Operation 6-3 Normal Mode Startup Confirm that the UPS system is properly grounded. Make sure the utility AC supply circuit breaker and the UPS system’s input breaker are switched off. Wire the utility AC supply circuit and output circuit to the UPS system’s terminal block and connect the external battery pack, following the instructions in Section 5 –...
  • Page 14: Battery Mode Startup (Cold Start)

    6 – Standard Operation 6-4 Battery Mode Startup (Cold Start) The UPS system supports battery mode startup (cold start), allowing it to operate as a standalone power source when AC input power is unavailable. Make sure the UPS system is properly installed and the battery is at least partially charged. Some electronic equipment may draw more amps during startup;...
  • Page 15 6 – Standard Operation 6-6 UPS System Settings and Measurements Settings and Special Functions After the UPS starts up completely, press button to execute special functions. Special functions include buzzer ON Buzzer “ON” Buzzer “OFF” Self-Test “OFF” Self-Test “ON” Bypass Acceptance Range #1 Changing Default Settings Make sure the UPS system is OFF .
  • Page 16: Parallel Redundancy Operation

    7 – Parallel Redundancy Operation (Optional) DANGER! LETHAL HIGH VOLTAGE HAZARD! All wiring should be performed by a qualified electrician, in accordance with the warnings in this manual and all applicable electrical and safety codes. Incorrect wiring may cause serious personal injury and property damage. Read, study and understand the warnings listed in Section 2 –...
  • Page 17: Communications

    8 – Communications Note: These connections are optional. The UPS system will function without these connections. 8-1 Network Card The UPS system includes an internal network card that provides an Ethernet interface for remote monitoring and control of the UPS system. Refer to the network card documentation for additional information.
  • Page 18: Troubleshooting

    Reconnect the RJ45 cable or set a UPS with ID=1. Have a qualified electrician check the AC supply circuit and wiring, then restart the UPS system. If the problem persists, contact Tripp Lite for service. Recharge the battery uninterrupted for 12 hours. If the problem persists, contact Tripp Lite for service and/or battery replacement.
  • Page 19: Specifications

    The UPS system is covered by the limited warranty described in this manual. Extended and on-site warranty options are also available. For more information, call Tripp Lite Customer Service at +1.773.869.1234. If returning the UPS system to Tripp Lite, carefully pack the UPS system using the original packing material that came with the unit.
  • Page 20: Battery Replacement

    12 – Battery Replacement DANGER! LETHAL HIGH VOLTAGE HAZARD! All service, including battery replacement, should be performed by qualified service personnel, in accordance with the warnings in this manual and all applicable electrical and safety codes. Read, study and understand the warnings listed in “Section 2 –...
  • Page 21: Warranty

    Regulatory Compliance Identification Numbers For the purpose of regulatory compliance certifications and identification, your Tripp Lite product has been assigned a unique series number. The series number can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to the series number. The series number should not be confused with the marking name or model number of the product.