LG LBUH366GSS0 Installation Manual page 24

Concealed duct
Table of Contents

Advertisement

Connecting Cables between Indoor Unit and Outdoor Unit
Clamping of cables
• Arrange 2 power cables on the control panel.
• First, fasten the steel clamp with a screw to the inner boss of control panel.
• For the cooling model, fix the other side of the clamp with a screw strongly.
For the heat pump model, put the 0.75mm
plastic clamp to the other boss of the control panel.
• In Australia, the length of power supply cord measured from the entry of the power supply cord to
the middle of live pin on the power plug should be over 1.8m.
Connecting the cable to the Outdoor Unit
• Remove the Cover control from the unit by loosening a screw.
Connect the wires to the terminals on the control board individually as following.
• Secure the cable onto the control board with the holder (clamper).
• Refix the cover control to the original position with the screw.
Outdoor unit
Over 5mm
CAUTION: After the confirmation of the above conditions, prepare the
wiring as follows:
1) Never fail to have an individual power specialized for the air conditioner. As for the method of wiring, be
guided by the circuit diagram pasted on the inside of control box cover.
2) Provide a circuit breaker switch between power source and the unit.
3) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from
vibrations to which the unit is subjected during the course of transportation. Check them and make sure
that they are all tightly fastened. (If they are loose, it could give rise to burn-out of the wires.)
4) Specification of power source
5) Confirm that electrical capacity is sufficient.
6) Be sure that the starting voltage is maintained at more than 90 percent of the rated voltage marked on
the name plate.
7) Confirm that the cable thickness is as specified in the power sources specification.
(Particularly note the relation between cable length and thickness.)
8) Never fail to equip a leakage breaker where it is wet or moist.
9) The following troubles would be caused by voltage drop-down.
• Vibration of a magnetic switch, damage on the contact point there of, fuse breaking, disturbance to the normal
function of a overload protection device.
• Proper starting power is not given to the compressor.
24 Concealed Duct Air Conditioner
2
cable(thinner cable) on the clamp and tighten it with a
Terminal block
Cord clamper
Power supply
cord
Cover control
Terminal block
Power cable