Functions Indoor Unit Operation ON/OFF by Remote controller Sensing the Room Temperature • Room temperature sensor. (Thermistor) Room temperature control • Maintains the room temperature in accordance with the Setting Temp. • Indoor fan is delayed for 5 seconds at the starting. Starting Current Control Time Delay Safety Control •...
2. Outdoor Unit Type: A Type: C Type: B (Unit: mm) Model No. TYPE LBUS3061BL LBUK3660BL LBUK4260BL 1220 LBUK4880BL 1220 LBUL6080BL 1220 LBUM7280BL 1,245 LBUM9080BL 1,245 LBUM1081BL 1,245 –8–...
Model : LB-K3660BL 1. Indoor (LBNK3661BL) INDOOR WIRING DIAGRAM RF REMOTE INDOOR DRAIN CONTROL MOTOR PUMP FUSE GN/YL GN/YL 250V10A PIPE THERMISTOR FLOAT S/W REMOTE CONTROL TERMINAL BLOCK OPTIONAL ZONE TELE CONTROL EXTRA CONTROL 3854A20172T 2. Outdoor (LBUK3660BL) P/NO : 3854A20026W Outdoor Unit Wiring Diagram C TH WIRING OF FIELD...
Page 12
Model : LB-K4260BL 1. Indoor (LBNK4261BL) INDOOR WIRING DIAGRAM RF REMOTE INDOOR DRAIN CONTROL MOTOR PUMP FUSE GN/YL GN/YL 250V10A PIPE THERMISTOR FLOAT S/W REMOTE CONTROL TERMINAL BLOCK OPTIONAL ZONE TELE CONTROL EXTRA CONTROL 3854A20172T 2. Outdoor (LBUK4260BL) P/No.:3854A20135J OUTDOOR UNIT WIRING DIAGRAM NC NO CN-Power C TH...
Page 13
Model : LB-K4880BL 1. Indoor (LBNK4881BL) INDOOR WIRING DIAGRAM RF REMOTE INDOOR DRAIN CONTROL MOTOR PUMP FUSE GN/YL GN/YL 250V10A PIPE THERMISTOR FLOAT S/W REMOTE CONTROL TERMINAL BLOCK OPTIONAL ZONE TELE CONTROL EXTRA CONTROL 3854A20172T 2. Outdoor (LBUK4880BL) Outdoor Unit Wiring Diagram C TH 3.D.P 52F1...
Page 14
Model : LB-L6080BL 1. Indoor (LBNL6081BL) INDOOR WIRING DIAGRAM RF REMOTE INDOOR DRAIN CONTROL MOTOR PUMP GN/YL GN/YL FUSE 250V10A PIPE THERMISTOR FLOAT S/W REMOTE CONTROL TERMINAL BLOCK OPTIONAL ZONE TELE CONTROL EXTRA CONTROL 3854A20172T 2. Outdoor (LBUL6080BL) Outdoor Unit Wiring Diagram C TH 52F1 S T N...
Page 15
Model : LB-M7280BL 1. Indoor (LBNM7281BL) INDOOR WIRING DIAGRAM RF REMOTE INDOOR DRAIN CONTROL MOTOR PUMP GN/YL GN/YL FUSE 250V10A PIPE THERMISTOR FLOAT S/W REMOTE CONTROL TERMINAL BLOCK OPTIONAL ZONE TELE CONTROL EXTRA CONTROL 3854A20172T 2. Outdoor (LBUM7280BL) OUTDOOR UNIT WIRING DIAGRAM P/NO.:3854A20021V 63H2 C TH...
Page 16
Model : LB-M9080BL/LB-M1081BL 1. Indoor (LBNM9081BL/LBNM1081BL) INDOOR WIRING DIAGRAM RF REMOTE INDOOR DRAIN CONTROL MOTOR PUMP GN/YL GN/YL FUSE 250V10A PIPE THERMISTOR FLOAT S/W REMOTE CONTROL TERMINAL BLOCK OPTIONAL ZONE TELE CONTROL EXTRA CONTROL 3854A20172T 2. Outdoor (LBUM9080BL/LBUM1081BL) OUTDOOR UNIT WIRING DIAGRAM C TH 3.P.D NO NC...
Operation Details (1) The function of main control 1. Time Delay safety Control • 3min ... The compressor is ceased for 3minutes to balance the pressure in the refrigeration cycle. (Protection of compressor) • 30sec ... The 4-way valve is ceased for 30sec. to prevent the refrigerant-gas abnormal noise when the Heating operation is OFF or switched to the other operation mode while compress is off.
Page 18
4. Heating Mode Operation (Except Cooling Model) The unit will operate according to the setting by the remote controller and the operation diagram is shown as following. Intake Air temp. minimum 3min Setting temp.+3°C (Compressor OFF) Setting temp. (Compressor ON) minimum minimum 1min...
6. Defrost Control • Defrost control is availavle 45 minutes later since heating mode operation started, and it will not prolong over 10 minutes. • Defrost control is carried out when the outdoor pipe temp. falls below -6°C for more than 3 minutes after 45 minutes passed from starting of heating operation.
Installation of Indoor, Outdoor Unit 1. Selection of the best location 1) Indoor unit Top view Inspection hole Select location (unit: mm) (600X600) Install the air conditioner in the location that satis- Control box fies the following conditions. • The place shall easily bear a load exceeding four times the indoor unit’s weight.
3. Remote Controller Installation • Although the room temperature sensor is in the indoor unit, the remote controller should be installed in such places away from direct sunlight and high humidity. Installation of the remote controller • Select places that are not splashed with water. •...
Page 23
REMOTE CONTROL PREPARATION(OPTIONAL) HOW TO MOUNT ONTO A WALL HOW TO INSERT BATTERIES HOW TO INSERT BATTERIES Remove the battery cover from the remote controller. • Do not use rechargeable batteries, • Slide the cover according to the arrow direction. such batteries differ from standard dry cells in shape, dimensions, and performance.
4. Connecting Cables between Indoor Unit and Outdoor Unit 1) Connecting cables to the Indoor Unit Connect the wires to the terminals on the control board individually according to the outdoor unit connection. • Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively •...
Perform the electrical wiring work according to the electrical ELECTRICAL WIRING wiring connection. • All wiring must comply with local requirements. Circuit Breaker • Select a power source that is capable of supply- Main ing the current required by the air conditioner. power source Switch box •...
5. Connecting Pipes to the Indoor Unit • Preparation of Piping Main cause of gas leakage is defect in flaring work. Carry out correct flaring work in the following procedure. 1) Cut the pipes and the cable. I Use the accessory piping kit or the pipes purchased locally.
Page 27
Piping Connection 1. Form the piping according to its routing. Avoid bend- ing and bending back the same piping point more Liquid side than three times. (This will result in hardening the pipe.) Indoor 2. After deforming the piping, align centers of the union unit fitting of the indoor unit and the piping, and tighten Outdoor...
Page 28
CAUTION 1. Install declination of the indoor unit is very important for the drain of the duct type air conditioner. 2. Minimum thickness of the insulation for the connecting pipe shall be 5mm. Front of view • The unit must be horizontal or declined to the drain hose connected when finished installation. Ceiling CORRECT INCORRECT...
• Drill the piping hole with 70mm dia, hole core drill. WALL Indoor Outdoor • Piping hole should be slightly slant to the outdoor side. 5~7mm INSULATION, OTHERS Insulate the joint and tubes completely. THERMAL INSULATION All thermal insulation must comply with local requirement. INDOOR UNIT Union for liquid pipe Thermal insulator for refrigerant pipe...
FORM THE PIPINGS Seal a small opening around the pipings 1. Wrap the connecting portion of indoor unit with with gum type sealer. the Insulation material and secure it with two Plastic Bands. (for the right pipings) • If you want to connect an additional drain hose, the end of the drain-outlet should keep distance Drain hose from the ground.
Page 31
2) Connection of power supply 1. Connect the power supply cord to the independent power supply. • Circuit breaker is required. 2. Operate the unit for fifteen minutes or more. 3) Evaluation of the performance 1. Measure the temperature of the intake and discharge air. 2.
Optional Operation 1) Two Thermistor System (1) Open the rear cover of the wired remote-controller to set the mode. (2) Select one of three selectable modes as follows. • Position 1: The room temperature is controlled by the thermistor of the main body. •...
2) Group Control(Optional Wiring) • You can use a group control operation after connecting the brown and yellow wire of each air-conditioner. • Remove the resistor "OP 7" in remote controller. • It operates maximum 16 Units by only one Wired Remote Controller, and each Unit starts sequentially to prevent overcurrent.
Cycle 1. Installation (Connecting the piping between indoor and outdoor unit) Liquid side Indoor unit Outdoor unit Gas side Gas cylinder Purge the air • Installation (1) Connect the piping between the indoor and (5) If there is no leakage, discharge R22 in piping outdoor unit firmly.
Page 35
2. Disconnection (on moving) Liquid side Indoor unit Outdoor unit Gas side Retrieving Tank • Disconnection (1) Attach the charging hose (manifold gage) to (6) Disconnect the piping between indoor and the service port. outdoor unit and then put on service cap to –...
3. Gas Charging (After Evacuation) Liquid side Indoor unit Open Outdoor unit 2-Way valve Gas side Open 3-Way valve Check valve Charging cylinder OPEN CLOSE • Procedure This is different from previous procedures. (1) Connect the charge hose to the charging Because you are charging with liquid refrigerant cylinder.
Cycle Troubleshooting Guide Trouble analysis 1. Check temperature difference between intake and discharge air and operating current. Temp. difference : approx. 0°C All amount of refrigerant leaked out Current : less than 80% of Check refrigeration cycle rated current Temp. Difference Refrigerant leakege Temp.
Electronic Parts Troubleshooting Guide Possible Trouble 1 : The unit does not operate. Check the FUSE Is the input voltage and the wiring diagram. of transformer AC230V? Is the input voltage Check the main P.C.B of IC03D about AC12V? pattern. Is the output voltage Exchange IC03D.
Page 39
Possible Trouble 2 : The indoor fan does not operate. Is it the HOT It is normal operation. START mode? Is IC01M operated Exchange IC01M. normally? Is the each Relay Exchange Relay. any problem? Check the fan motor and connector.(CN-MOTOR) Possible Trouble 3 : Ineffective Heating Adjust operation mode.
Page 40
Possible Trouble 4 : Wired remote controller does not operate. Check the parts of Is the LCD operated communication. normally? Connector CN-Remo, and Is the terminal of wired terminals of wired Remocon T2 DC12V? Remocon exactly. Check the wired Remocon Is the pin 39, 40 of PCB and DC 12V pattern.
Parts List • Model: LBUK4880BL/LBUL6080BL Part No. LOCATION NO DESCRIPTION REMARKS LBUK4880BL LBUL6080BL 435301 GRILLE ASSY, DISCHARGE(OUTDOOR) 3530AP1225D 3530AP1225D 430410 BASE ASSY, WELD(OUTDOOR) 3041AP2569B 3041AP2569B 435511 COVER ASSY, CONTROL(OUTDOOR) 3A01293X 3A01293X 435512 COVER ASSY, TOP(OUTDOOR) 3550AP1213B 3550AP1213B 437210 PANEL ASSY, FRONT(OUTDOOR) 3720AP1212B 3720AP1212B 437212...
Page 59
2. Outdoor Unit • Model: LBUM7280BL –59–...
Page 60
Parts List • Model: LBUM7280BL LOCATION NO. DESCRIPTION REMARKS Part No. 430411 BASE ASSY 3041AP2606V 554160 COMPRESSOR 5416AP2667F 548490 ACCUMULATOR 3A02139U 649950 CONTROL BOX ASSY 4995A20002E W6640-6 TERMINAL BLOCK 3A00493A W6640-1 TERMINAL BLOCK 4G00103A 566001-4 SWITCH, MAGIVET 2A01031K W0CZZ-5 CAPACITOR, DRAWING 2H00841J W6920 RELAY...
Page 61
Parts List • Model: LBUM7280BL LOCATION NO DESCRIPTION REMARKS Part No. W49810-2 SUPPORT VALVE 4980AP2621A W4810 BRACKET FRONT 4810AP7078A 552203-1 VALVE SERVICE 2A00469H 552203-2 VALVE SERVICE 2A00468C W49810-3 SUPPORTER REAR 4980AP1265Q W49810-4 SUPPORTER REAR 4980AP1265P W49810-5 SUPPORTER FRONT 4980AP1264P W49810-6 SUPPORTER FRONT 4980AP1263P 349490...
Page 62
2. Outdoor Unit • Model: LBUM9080BL/LBUM1081BL –62–...
Page 63
Parts List • Model: LBUM9080BL/LBUM1081BL Part No. LOCATION NO DESCRIPTION REMARKS LBUM9080BL LBUM1081BL 430411 BASE ASSY 3041A10037D 3041A10037D 649950 CONTROL BOX ASSY 4995A20002H 4995A20002H W6640-1 TERMINAL BLOCK 3A00493A 3A00493A W6640-2 TERMINAL BLOCK 4G00103A 4G00103A 566001-4 SWITCH, MAGNET 6600B000041 6600B000041 W0CZZ CAPACITOR, DRAWING 2A00986D 2A00986D...