Performance Data; Cooling Capacity - Sanyo SA-123A Technical & Service Manual

Window type air conditioner
Table of Contents

Advertisement

5. PERFORMANCE DATA

5-1. Cooling Capacity

Model
SA–123A
240V Single Phase 50Hz
RATING CAPACITY
AIR FLOW RATE
EVAPORATOR
ENT. TEMP. °C
W.B.
15
17
19
21
23
TC :
SHC : Sensible Heat Capacity (kW)
CM : Compressor Input (kW)
Rating conditions (#Mark) are
3.50 kW
520 m
D.B.
20
TC
3.53
CM
0.96
21
SHC
2.45
23
SHC
2.80
25
SHC
3.15
27
SHC
3.49
29
SHC
3.53
31
SHC
3.53
TC
3.78
CM
0.99
21
SHC
2.09
23
SHC
2.43
25
SHC
2.78
27
SHC
3.13
29
SHC
3.48
31
SHC
3.78
TC
4.03
CM
1.02
21
SHC
1.71
23
SHC
2.06
25
SHC
2.41
27
SHC
2.75
29
SHC
3.10
31
SHC
3.45
TC
4.27
CM
1.05
23
SHC
1.68
25
SHC
2.03
27
SHC
2.37
29
SHC
2.72
31
SHC
3.07
TC
4.53
CM
1.07
25
SHC
1.63
27
SHC
1.98
29
SHC
2.32
31
SHC
2.67
Total Cooling Capacity (kW)
Outdoor Ambient Temp. 35°C D.B.
Indoor Unit Entering Air Temp. 27°C D.B. / 19°C W.B.
3
/h
CONDENSER
OUTDOOR AMBIENT TEMP. °C
25
30
3.37
3.22
1.04
1.11
2.37
2.30
2.72
2.65
3.07
3.00
3.37
3.22
3.37
3.22
3.37
3.22
3.62
3.45
1.07
1.15
2.01
1.94
2.36
2.29
2.71
2.63
3.06
2.98
3.40
3.33
3.62
3.45
3.85
3.68
# 3.50
1.10
1.18
1.63
1.56
1.98
1.91
2.33
2.26
2.68
2.61
3.03
2.96
3.38
3.30
4.08
3.90
1.13
1.21
1.60
1.53
1.95
1.88
2.30
2.23
2.65
2.58
3.00
2.93
4.33
4.13
1.16
1.25
1.56
1.48
1.90
1.83
2.25
2.18
2.60
2.53
7
35
40
43
3.07
2.88
2.65
1.20
1.32
1.45
2.23
2.14
2.03
2.57
2.49
2.38
2.92
2.84
2.65
3.07
2.88
2.65
3.07
2.88
2.65
3.07
2.88
2.65
3.29
3.09
2.85
1.23
1.36
1.49
1.86
1.78
1.67
2.21
2.13
2.02
2.56
2.47
2.37
2.91
2.82
2.72
3.26
3.09
2.85
3.29
3.09
2.85
3.29
3.03
1.27
1.40
1.53
1.49
1.40
1.30
1.84
1.75
1.65
2.19
2.10
2.00
2.53
2.45
2.34
2.88
2.80
2.69
3.23
3.15
3.03
3.71
3.49
3.21
1.30
1.44
1.57
1.46
1.38
1.27
1.81
1.73
1.62
2.16
2.07
1.97
2.51
2.42
2.32
2.85
2.77
2.67
3.90
3.65
3.39
1.34
1.47
1.61
1.40
1.31
1.23
1.75
1.66
1.58
2.10
2.01
1.93
2.45
2.36
2.27

Advertisement

Table of Contents
loading

This manual is also suitable for:

185100695

Table of Contents