FEATURES

CONTROL PANEL FEATURES

1
W
7500 Running Watts | 9500 Peak Watts
1
Push Button Electric Start:
• Push for 1 second to automatically start the
engine.
• Push again to stop the engine.
Engine Control Switch/Battery Disconnect:
2
Switch to "Stop" to stop the engine. When in
"Stop" position it prevents the unit from drawing
power from the battery. Switch to "Run" before
starting engine.
Data Center: The VFT Meter is 4 state LED display
3
that will rotate through volts, frequency, and lifetime
run hours. The 4th display is not used and will
always display 00:00. You can press the MODE
button to cycle through the different displays. The
meter will display volts and hertz even if there is no
load connected.
The frequency and voltage can vary +/- 5% and
still be within tolerance.
14 | Westinghouse Portable Power
2
3
Gen7500
8
9
Voltage
Frequency in hertz
Lifetime run hours
Inoperative
4
5
SMARTŁ
SWITCHŁ
READY
10
11
4
Main Circuit Breaker: The main circuit breaker
controls total output of all outlets to protect the
generator.
5
120/240-Volt, 30-Amp Twist Lock Outlet
(NEMA L14-30R): Outlet can supply either
120V or 240V output.
6
120-Volt, 20-Amp Duplex GFCI Outlets
(NEMA 5-20R): Each outlet is capable of carrying
a maximum of 20 amps on a single receptacle or
a combination of both receptacles.
7
20-Amp Circuit Breakers: Each circuit breaker
limits the current that can be delivered through
the 120-volt duplex outlets to 20amps.
8
Battery Charge Port: Engine control switch must
be in OFF position to charge with included charger.
Used in conjunction with the Westinghouse ST
Switch (sold separately) when the generator is in
standby mode to charge the battery.
9
Battery Indicator Light: When light is illuminated,
the battery is connected and providing power to
the electronics.
10
Smart Switch Outlet: Connects the
Westinghouse ST Switch (sold separately) to the
control panel.
11
Ground Terminal: The ground terminal is used to
ground the generator.
6
7