GETTING STARTED GUIDE
NI PXIe-5632
8.5 GHz Full Two-Port Vector Network Analyzer
Note
Before you begin, install and configure your chassis and controller.
This document explains how to install, configure, and test the NI PXIe-5632 (NI 5632). The
NI 5632 is a 8.5 GHz, 2-port vector network analyzer (VNA) with support for full S-parameter
measurements. The NI 5632 ships with the NI-VNA instrument driver, which you can use to
program the device.
To access NI 5632 documentation, navigate to Start»All Programs»National Instruments»
NI-VNA»Documentation.
The specifications document for your device is installed with the driver software. Refer to
ni.com/manuals
for the most recent specifications for your device.
Caution
manner not described in this document.
Contents
Electromagnetic Compatibility Guidelines...............................................................................2
Verifying the System Requirements......................................................................................... 2
Unpacking the Kit..................................................................................................................... 2
Verifying the Kit Contents................................................................................................ 3
Preparing the Environment....................................................................................................... 4
Installing the Software.............................................................................................................. 5
Installing the NI 5632............................................................................................................... 5
Connecting Signals........................................................................................................... 7
Configuring the NI 5632 in MAX...........................................................................................11
Programming the NI 5632...................................................................................................... 13
NI-VNA Examples......................................................................................................... 13
Making Uncalibrated Measurements with the NI 5632..........................................................14
Calibrating the NI 5632.......................................................................................................... 14
Making Calibrated Measurements with the NI 5632..............................................................15
Troubleshooting...................................................................................................................... 16
What Should I Do if the Module Fails the Self-Test?.....................................................16
Why Is the ACCESS LED Off When the Chassis is On?...............................................16
What Should I Do if the NI 5632 Doesn't Appear in MAX?..........................................16
Where to Go Next................................................................................................................... 18
Worldwide Support and Services............................................................................................18
The protection provided by this product may be impaired if it is used in a

Advertisement

Table of Contents
loading

Summary of Contents for National Instruments PXIe-5632

  • Page 1: Table Of Contents

    Before you begin, install and configure your chassis and controller. This document explains how to install, configure, and test the NI PXIe-5632 (NI 5632). The NI 5632 is a 8.5 GHz, 2-port vector network analyzer (VNA) with support for full S-parameter measurements.
  • Page 2: Electromagnetic Compatibility Guidelines

    Furthermore, any modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules.
  • Page 3: Verifying The Kit Contents

    0.9 N · m (8 in-lb) torque wrench Optional Items • PXI Chassis Slot Blocker kit (NI part number 199198-01) • The following accessories available on the NI 5632 product page at ni.com/products: NI PXIe-5632 Getting Started Guide | © National Instruments | 3...
  • Page 4: Preparing The Environment

    Clean the hardware with a soft, nonmetallic brush. Make sure that the hardware is completely dry and free from contaminants before returning it to service. Note Refer to the NI PXIe-5632 Specifications at ni.com/manuals for complete specifications. 4 | ni.com | NI PXIe-5632 Getting Started Guide...
  • Page 5: Installing The Software

    2. PXI Peripheral Slot 5. PXI Express Peripheral Slot 3. PXI Express Hybrid Peripheral Slot The NI 5632 can be placed in PXI Express peripheral slots or PXI Express Hybrid peripheral slots. NI PXIe-5632 Getting Started Guide | © National Instruments | 5...
  • Page 6 11. Cover all empty slots using filler panels or slot blockers to maximize cooling air flow. 12. Power on the chassis. Related Information Installing the Software on page 5 6 | ni.com | NI PXIe-5632 Getting Started Guide...
  • Page 7: Connecting Signals

    The NI 5632 is a precision RF instrument that is sensitive to ESD and transients. Ensure you take the following precautions when making direct connections to the NI 5632 to avoid damaging the device. NI PXIe-5632 Getting Started Guide | © National Instruments | 7...
  • Page 8 0 VDC +27 dBm MAX 0 VDC REF IN +20 dBm MAX 50 VDC SOURCE 1 PORT 2 +27 dBm MAX +27 dBm MAX 50 VDC 0 VDC SENSITIVE ALL RF PORTS 8 | ni.com | NI PXIe-5632 Getting Started Guide...
  • Page 9 SOURCE 1 OUT Output terminal for the source 1 access loop. SOURCE 2 OUT Output terminal for the source 2 access loop. PORT 2 Input terminal for NI 5632 measurements. NI PXIe-5632 Getting Started Guide | © National Instruments | 9...
  • Page 10 Make sure to use the proper connectors to mate with the NI 5632. NI recommends that you use precision or instrument or metrology grade Type-K, 2.92 mm, 3.5 mm, or SMA connectors. 10 | ni.com | NI PXIe-5632 Getting Started Guide...
  • Page 11: Configuring The Ni 5632 In Max

    MAX is automatically installed with NI-VNA. Launch MAX. In the Configuration pane, double-click Devices and Interfaces to see the list of installed devices. Installed devices appear under the name of their associated chassis. NI PXIe-5632 Getting Started Guide | © National Instruments | 11...
  • Page 12 The MAX self-test performs a basic verification of hardware resources. Related Information What Should I Do if the Module Fails the Self-Test? on page 16 What Should I Do if the NI 5632 Doesn't Appear in MAX? on page 16 12 | ni.com | NI PXIe-5632 Getting Started Guide...
  • Page 13: Programming The Ni 5632

    NI-VNA Examples Examples demonstrate the functionality of the device and serve as programming models and building blocks for your own applications. The NI Example Finder is a utility available for NI PXIe-5632 Getting Started Guide | © National Instruments | 13...
  • Page 14: Making Uncalibrated Measurements With The Ni 5632

    Remove the DUT. Calibrating the NI 5632 Frequent calibration is particularly important for the NI 5632 because it allows you to remove certain errors from the actual measurements. Calibration removes errors caused by 14 | ni.com | NI PXIe-5632 Getting Started Guide...
  • Page 15: Making Calibrated Measurements With The Ni 5632

    Ensure you are applying the proper correction from the Calibrating the NI 5632 section. Measure and save the DUT parameters. Verify that the calibrated measurement falls within your expected range. NI PXIe-5632 Getting Started Guide | © National Instruments | 15...
  • Page 16: Troubleshooting

    Expand the Chassis tree to see the list of installed devices, and press <F5> to refresh the list. If the module is still not listed, power off the system, ensure that all hardware is correctly installed, and restart the system. 16 | ni.com | NI PXIe-5632 Getting Started Guide...
  • Page 17 If you are using a PXI controller, verify that a National Instruments entry appears in the system device list and that the NI PXIe-5632 is enabled. If the device is disabled, right- click NI PXIe-5632, and select Enable from the shortcut menu. If you are using a MXI controller, right-click PCI-to-PCI Bridge, and select Properties from the shortcut menu to verify that the bridge is enabled.
  • Page 18: Where To Go Next

    RF fundamentals, device features, and programming with NI-VNA. Worldwide Support and Services The National Instruments website is your complete resource for technical support. At ni.com/ support, you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers.
  • Page 19 National Instruments corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. National Instruments also has offices located around the world. For telephone support in the United States, create your service request at ni.com/support...
  • Page 20 NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS.

Table of Contents