Natural Gas - Cal Flame FRP-910-3 Owner's Manual

Table of Contents

Advertisement

12

Natural Gas

Ensure that the service supplying the fireplace is fitted with a conve-
niently positioned shut off valve with easy access. The shut off valve
MUST NOT be inside the appliance!
Requirements
Always check the rating plate to make sure the gas supply you are
hooking up to is the gas type the fireplace is manufactured for.
The installation of this appliance must conform with local codes or,
in the absence of local codes, to the national fuel gas code, ANSI
Z223.1a-1998. Natural gas connection must be performed by a li-
censed contractor or local gas company representative.
Ensure that the service supplying the fireplace is fitted with a conve-
niently positioned shut off valve with easy access.
Installation
Connect the incoming gas supply line to the on/off gas valve of the
appliance. Make certain ALL gas connections are tight, turn the on/
off valve at the unit to the 'on' position and use soap and water to
test for leaks. Gas will be released at the burner for this duration. DO
NOT USE AN OPEN FLAME AND REMOVE BATTERY FROM IGNITER
BEFORE PERFORMING THIS TEST. An authorized gas appliance
installer must provide this installation service. Note that the
correct natural gas orifice must also be installed prior to fuel line hook
up to maintain proper flame height and clean burn of fuel.
Fireplace Owner's Manual
LTR50001006, Rev. P
www.cal amebbq.com