− To remove the electronic controller.
− Remove the particular piece (Fig. 4)
− Release CN-FM connector (Fig. 4)
− Release CN-Sonic connector (Fig. 4)
− Release CN-FB connector (Fig. 4)
− Release CN-ION connector (Fig. 4)

12.3. Indoor Fan Motor and Cross Flow Fan Removal Procedures

• Remove Control Board cover
− Remove the screw on the left side of the unit. (Fig. 6)
− Pull the hook to the left and lift up the evaporator. (Fig.
6)
− Pull down the Discharge Grille Complete. (Fig. 6)
Fig. 4
Fig. 6
− Release CN-TH connector (Fig. 4)
− Release CN-STM connector (Fig. 4)
− Release CN-REC/DISP connector (Fig. 4)
− Press the hook to the right then take out the PCB(Fig. 5)
− Remove Ry-Pwr connector (black and brown) and Ac-
Wht connector from the PCB. (Fig. 5)
− Remove indoor pipe sensor and air intake sensor from
the evaporator. (Fig. 7)
55
CS-C9DKZW CU-2C18DKH / CS-C9DKZW CU-3C20DKH
Fig. 5
Fig. 7
Fig. 8

Advertisement