Panasonic CS-C9DKZW Service Manual page 5

Table of Contents

Advertisement

Outdoor Unit
CU-2C18DKH & CU-3C20DKH
Compressor Reverse Rotation
Protection Control
• To protect compressor from reverse
rotation when there is a instantaneous
power failure.
Overload Protector
• 2-stage OLP to protect the compressor.
Overload Protector will trip when
– Temperature of compressor increases
to 120°C.
– High temperature or high current flows
to compressor.
(Refer circuit diagram for OLP
characteristic)
60 Sec. Forced Operation Control
• Once the compressor is activated, it
does not stop within the first 60 sec.
However, it stops immediately when
received stop signal from remote control.
Outdoor Fan Operation Control
5
CS-C9DKZW CU-2C18DKH / CS-C9DKZW CU-3C20DKH