Unit Dimensions - Front; Unit Minimum Clearances - York DYP024 Installation Manual

Single packaged gas/ electric air cooled, air conditioners
Table of Contents

Advertisement

GAS SUPPLY 1-1/4" DIA.
HOLE (1/2" NPTF
CONNECTION)
UNIT CONDENSATE
CONNECTION 3/4" NPTF
(TRAP RECOMMENDED)
B
HIGH VOLTAGE
CONN. 1-3/8" DIA.
3-3/4
KNOCKOUT
HIGH VOLTAGE
CONN. 7/8" DIA.
2-1/2
KNOCKOUT
GAS SUPPLY 1-1/4" DIA.
KNOCKOUT (1/2" NPTF
CONNECTION)
LOW VOLTAGE CONN.
1-3/8" DIA. KNOCKOUT
X 7/8" HOLE
FIGURE 10 - UNIT DIMENSIONS - FRONT
TABLE 11: UNIT DIMENSIONS FRONT
UNIT SIZE
"A"
024, 030, 036
33-1/2
042, 048, 060
41-1/2
Johnson Controls Unitary Products
VENT AIR OUTLET HOOD
BLOWER SERVICE
ACCESS COMPARTMENT
PANEL
47-1/4
(OVERALL)
DIMENSION
"B"
18-1/4
23-1/8
5-3/8
1-1/2
11
12-3/4
3-1/3
2-5/8
TABLE 12: UNIT MINIMUM CLEARANCES
FRONT
BACK
LEFT SIDE (Filter-Access)
RIGHT SIDE
BELOW UNIT
ABOVE UNIT
1. A 1" clearance must be provided between any combus-
tible material and the supply air ductwork.
2. The products of combustion must not be allowed to
accumulate within a confined space and recirculate.
3. Units may be installed on combustible floors made from
wood or class A, B, or C roof covering material.
4. Units must be installed outdoors. Overhanging struc-
tures or shrubs should not obstruct condenser air dis-
charge outlet.
284720-BIM-D-0909
CONDENSER COIL
A
2-3/8
REFRIGERANT
CONNECTIONS
COMBUSTION AIR
INLET LOUVERS
FRONT
GAS/ELECTRIC CONTROL
49-1/8
SERVICE ACCESS
COMPARTMENT PANEL
(OVERALL)
CLEARANCES
3
4
36" (For Condenser Air Discharge
1 2
36"
0"
24"
12"
0"
15