Siemens SIMATIC NET RUGGEDCOM RS900 Installation Manual page 47

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RS900:
Table of Contents

Advertisement

Certification
6.2 EMC and Environmental Type Tests
Dielectric Strength
Environmental Type Tests
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60255-21-1
IEC 60255-21-2
38
Description
HV Impulse
Test
Cold Temperature
Dry Heat
Humidity (Damp
Heat, Cyclic)
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Description
Test Ad
Test Bd
Test Db
Vibration
Shock
Test Levels
5 kV (Failsafe Relay)
5 kV
5 kV
2 kV (Failsafe Relay)
1.5 kV
2 kV
Test Levels
Severity Levels
-40 °C (-40
°F), 16 Hours
85 °C (185
°F), 16 Hours
95% (Non-
Condensing),
55 °C (131
°F), 6 Cycles
2 g @ 10 to 150 Hz
30 g @ 11 ms
Installation Manual, 04/2022, C79000-G8976-1024-14
 
 
 
Class 2
Class 2
RUGGEDCOM RS900

Advertisement

Table of Contents
loading

Table of Contents