Maintenance scHeduLe

annually (Before the onset of the Burning Season)
Maintenance tasK
Inspecting/Cleaning Burner, Logs
and Controls
Check Flame Patterns and Flame
Height
Inspecting/Cleaning Pilot and Burner
Checking Vent System
Appliance Checkout
Replacing Rockwool Ember Materials
periodically (After the Burning Season)
Maintenance tasK
Cleaning Firebox Interior
Check Flame Patterns and Flame
Height
Checking Vent System
Cleaning Front Glass Enclosure Panel
20
accoMpLisHinG person
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Homeowner/Qualified Service
Technician
accoMpLisHinG person
Homeowner
Homeowner
Homeowner
Homeowner
procedure
Inspect valve and ensure it is properly operating. Check piping
for leaks. Vacuum the control compartment, fireplace logs and
burner area.
Refer to Figure 9 (SLDVT-35) or Figure 10 (SLDVT-40) on Page
10 and verify the flame pattern and height displayed by the ap-
pliance conforms to the picture. Flames must not impinge on
the logs. Ensure flames are steady (not lifting or floating).
Refer to Figure 12 (SIT Millivolt) or Figure 13 (Electronic) on
Page 11. Remove any surface build-up on pilot and burner
assembly. Wipe the pilot nozzles, igniter/flame rod and hood.
Ensure the pilot flame engulfs the flame sensor as shown.
Inspect the vent system at the top and at the base (within the
firebox) for signs of blockage or obstruction. Look for any signs
of dislocation or deterioration of the vent components. Note:
Excessive condensation can cause corrosion of caps, pipe &
fittings (excessive condensation can be caused by long lateral
runs, too many elbows and/or exterior portions of the system
being exposed to cold weather). Also inspect wall straps or
plumbers's tape to ensure it is secure and in place.
Perform the appropriate appliance checkout procedure detailed
in this manual.
Remove old ember materials (rockwool) and vacuum the ember
placement area. Place new embers as described and shown in
Figures 7 & 8.
procedure
Carefully remove logs, rockwool, volcanic stone and vermiculite.
Vacuum out interior of the firebox. Clean firebox walls and log
grate. Replace logs, rockwool, vermiculite and volcanic stone
as detailed in this manual.
Refer to Figure 9 (SLDVT-35) or 10 (SLDVT-40) on Page 10
and verify the flame pattern and height displayed by the ap-
pliance conforms to the picture. Flames must not impinge on
the logs.
Inspect the vent system at the top and at the base (within the
firebox) for signs of blockage or obstruction. Look for any signs
of dislocation of the vent components.
Clean as necessary following the directions provided in this
manual. do not toucH or atteMpt to cLean GLass
WHiLe Hot.