Subaru RGX2900 Generator User Manual

Subaru robin power products portable generator - power generator user manual
Hide thumbs Also See for RGX2900:

Advertisement

3ZZ9990184
(英・露・亜)

Advertisement

Table of Contents
loading

Summary of Contents for Subaru RGX2900

  • Page 1 3ZZ9990184 (英・露・亜)
  • Page 2 Thank you for purchasing a This manual covers operation and maintenance of the Robin generators. All information in this publication is based on the latest production information available at the time of approval for printing. Pay special attention to statements preceded by the following words: WARNING Indicates a strong possibility of severe personal injury, loss of life and equipment damage if instructions are not followed.
  • Page 3: Table Of Contents

    1. SAFETY PRECAUTIONS ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ 1 2. SPECIFICATIONS ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ 3 3.
  • Page 4: Safety Precautions

    1. SAFETY PRECAUTIONS Please make sure you review each precaution carefully. WARNING Do not operate the generator near gasoline or gaseous fuel because of the potential danger of explosion or fire. Do not fill the fuel tank with fuel while the engine is running. Do not smoke or use open flame near the fuel tank.
  • Page 5 WARNING Do not operate in rain, in wet or damp conditions, or with wet hands. The operator may suffer severe electric shock if the generator is wet due to rain or snow. WARNING If wet, wipe and dry it well before starting. Do not pour water directly over the generator, nor wash it with water.
  • Page 6: Specifications

    Rated continuous operation Engine oil capacity Spark plug Starting system Length Width Hight Dry weight Specifications are subject to change without notice. RGX2900 Brush-less, self-exciting, 2-poles, single phase V-Hz 220-50, 240-50, 230-50, 120/240-60 50Hz 60Hz 50Hz 60Hz Fuse-less circuit breaker...
  • Page 7: Components

    3. COMPONENTS Fuel tank Fuel strainer ( Fuel cock ) Recoil starter handle Recoil starter Fuel gauge Muffler cover Engine switch Oil gauge (oil filler) Oil drain plug Tank cap Exhaust outlet − 4− Control panel Spark plug cap Choke lever Air cleaner...
  • Page 8: Control Panel

    CONTROL PANEL RGX2900 (50Hz-220V, 240V) AC receptacle DC output DC circuit terminal breaker RGX3600 (50Hz-220V, 240V) AC receptacle DC output DC circuit terminal breaker RGX4800 (50Hz-220V, 240V) AC receptacle DC output DC circuit terminal breaker (60Hz-120/240V) Voltmeter AC circuit breaker...
  • Page 9 RGX2900 (50Hz-230V) AC receptacle DC output DC circuit terminal breaker RGX3600 (50Hz-230V) AC receptacle DC output DC circuit terminal breaker RGX4800 (50Hz-230V) AC receptacle DC output DC circuit terminal breaker Voltmeter AC circuit breaker Earth ( ground ) terminal Voltmeter...
  • Page 10: Pre-Operation Checks

    Oil capacity (Upper level) : RGX2900 ....0.6 RGX3600 ....0.6 RGX4800 .
  • Page 11: Check Engine Fuel

    CHECK ENGINE FUEL. WARNING Do not refuel while smoking or near open flame or other such potential fire hazards. Otherwise fire accident may occur. Check fuel level at fuel level gauge. ■ If fuel level is low, refill with ■ unleaded automotive gasoline.
  • Page 12 CHECKING COMPONENT PARTS Check following items before starting engine: Fuel leakage from fuel hose, etc. ■ Bolts and nuts for looseness. ■ Components for damage or breakage. ■ Generator not resting on or against any adjacent wiring. ■ CHECK GENERATOR SURROUNDINGS WARNING Make sure you review each warning in order to prevent fire hazard.
  • Page 13: Operating Procedures

    5. OPERATING PROCEDURES STARTING THE GENERATOR [ CAUTION ] Check the oil level before each operations as outlined by the article "CHECK ENGINE OIL" (a) Turn the Engine switch to the position "ON". (b) Turn the AC circuit breaker to the position "OFF".
  • Page 14 (e) Pull the starter handle slowly until resistance is felt. This is the "compression" point. Return the handle to its original position and then pull swiftly. If the engine fails to start after several ■ attempts, repeat above procedures with choke lever returned to "OPEN" position.
  • Page 15: Using Electric Power

    USING ELECTRIC POWER WARNING Make sure that the appliance is switched OFF before connecting it to ■ the generator. Do not move the generator while it is running. ■ Be sure to ground the generator if the connected appliance is ■...
  • Page 16 Up to total 15 ampere from two receptacles Up to 15 amperes WARNING To take power out from the TWIST ■ LOCK RECEPTACLE, insert the plug into the receptacle, and turn it clockwise to the lock position. Be sure to ground the generator if ■...
  • Page 17 Dual voltage type (RGX4800) FULL POWER SWITCH (a) Select the voltage using the FULL POWER SWITCH in accordance with the electrical appliance. Refer to TABLE 2. [ CAUTION ] Change the FULL POWER SWITCH after turning the AC circuit breaker to "OFF".
  • Page 18 (2) DC APPLICATION The DC terminal is used only for charging 12 volt batteries. It provides up to 12V-8.3A (100W) of maximum power. CONNECTION OF CABLE : Connect positive (red) terminal on ■ generator to positive (+) terminal on battery. Connect negative (black) terminal on ■...
  • Page 19 STOPPING THE GENERATOR (a) Turn off the power switch of the electric equipment and unplug the cord from receptacle of the generator. (b) Turn the AC circuit breaker to the "OFF" position. (c) Allow the engine about 3 minutes to cool down at no-load before stopping.
  • Page 20: Wattage Information

    The voltage and amperage (amps) information can be found on a name plate which is normally attached to electrical appliances and tools. Applications Incandescent lamp, Heater Fluorescent lamp, Electric tool Mercury lamp Pump, Compressor Applicable Wattage (W) RGX2900 RGX3600 50Hz 60Hz 50Hz 2000 2400 2400...
  • Page 21 VOLTAGE DROP IN ELECTRIC EXTENSION CORDS When a long electric extension cord is used to connect an appliance or tool to the generator, a certain amount of voltage drop or loss occurs in the extension cord which reduces the effective voltage available for the appliance or tool. The chart below has been prepared to illustrate the approximate voltage loss when an extension cord of 300 feet (approx.
  • Page 22: Maintenance Schedule

    7. MAINTENANCE SCHEDULE DAILY EVERY 50 HOURS EVERY 100 HOURS EVERY 200 HOURS EVERY 500 HOURS EVERY 1,000 HOURS (24 MONTHS) NOTE : ( * ) Initial oil change should be performed after first twenty (20) hours of use. ■ Thereafter change oil every 100 hours.
  • Page 23: How-To" Maintenance

    8. "HOW-TO" MAINTENANCE ENGINE OIL CHANGE Change engine oil every 100 hours. ■ (For new engine, change oil after 20 hours.) (a) Drain oil by removing the drain plug and the oil filler cap while the engine is warm. (b) Reinstall the drain plug and fill the engine with oil until it reaches the upper level on the oil filler cap.
  • Page 24: Cleaning And Adjusting Spark Plug

    CLEANING AND ADJUSTING SPARK PLUG (a) If the plug is contaminated with carbon, remove it using a plug cleaner or wire brush. (b) Adjust the electrode gap to 0.6 to 0.7 mm (0.024 to 0.028 in.). Spark plug : BR-6HS (NGK) or RL86C (CHAMPION) CLEANING FUEL STRAINER Dirt and water in the fuel are removed by the fuel strainer.
  • Page 25: Preparation For Storage

    9. PREPARATION FOR STORAGE The following procedures should be followed prior to storage of your generator for periods of 6 months or longer. Drain fuel from fuel tank carefully by ■ disconnecting the fuel line. Gasoline left in the fuel tank will eventually deteriorate making engine- starting difficult.
  • Page 26: Troubleshooting

    10. TROUBLESHOOTING When generator engine fails to start after several attempts, or if no electricity is available at the output socket, check the following chart. If your generator still fails to start or generate electricity, contact your nearest for further information or corrective procedures. When Engine Fails to Start : Check if choke lever is in its proper position.
  • Page 27: Wiring Diagram

    11. WIRING DIAGRAM RGX2900 (50Hz-220V, 240V) ENGINE Ignition Oil sensor coil control unit GENERATOR Condenser Winding RGX2900 (60Hz-120/240V) ENGINE Ignition Oil sensor coil control unit GENERATOR Condenser Winding CONTROL BOX Engine switch AC circuit breaker Voltmeter DC circuit breaker Diode stack...
  • Page 28 RGX3600 (50Hz-220V, 240V) ENGINE Ignition Oil sensor coil control unit GENERATOR Condenser Winding RGX3600 (60Hz-120/240V) ENGINE Ignition Oil sensor coil control unit GENERATOR Condenser Winding CONTROL BOX Engine switch AC circuit breaker Voltmeter DC circuit breaker Diode stack Assy Brn/W Condenser CONTROL BOX Engine switch...
  • Page 29: Control Box

    RGX4800 (50Hz-220V, 240V) ENGINE Ignition Oil sensor coil control unit GENERATOR Condenser Winding RGX4800 (60Hz-120/240V) ENGINE Ignition Oil sensor coil control unit GENERATOR Condenser Winding CONTROL BOX AC circuit breaker Voltmeter DC circuit breaker Diode stack Assy Brn/W Condenser Condenser CONTROL BOX AC circuit breaker REC3...
  • Page 30 RGX2900 / 3600 (50Hz-230V) ENGINE Ignition Oil sensor coil control unit GENERATOR Condenser Winding RGX4800 (50Hz-230V) ENGINE Ignition Oil sensor coil control unit GENERATOR Condenser Winding CONTROL BOX Engine switch AC circuit breaker Voltmeter DC circuit breaker Diode stack Assy...
  • Page 31 ISSUE EMD-GU2149 PRINTED IN JAPAN August 2005 CE-SK...

This manual is also suitable for:

Rgx3600Rgx4800Rgx3600

Table of Contents