59 Forced drain
Notice (e.g.
60
maintenance)
Compressor run
64
time reset
LED run time
65
reset
Number of
66
chemical doses
reset
Auto-reset error
67
check
Low water shut
69
down
Err Error history
Fre Freeze cycle time
Harvest cycle
HAr
time
Evaporator outlet
EVA
temperature
Condenser
Con
temperature
Number of freeze
FCt
cycles
UV-LED
ut
irradiation time
Total number of
Sct
chemical doses
Compressor run
CCt
time
VEr Software version Show software version.
Model code
Cod
change
When "drn" is selected, unit de-energizes
every component, drain ("drn"), and shuts
down ("oFF"). If reset button is pressed
during drain cycle, unit shuts down.
Notice code "n99" appears after set period of
time.
Reset compressor run time counting
(maintenance mode).
Reset LED run time counting (maintenance
mode).
Reset number of chemical doses for fully
automated cleaning kit (maintenance mode).
When "err" is selected, display shows
ongoing auto-reset errors.
If low water is detected in fill cycle, unit shuts
down for water leak error.
Show last ten errors.
Show freeze cycle time (min) for last ten
cycles.
Show harvest cycle time (min) for last ten
cycles.
Show evaporator outlet thermistor
temperature.
Show condenser outlet thermistor
temperature.
Show number of freeze cycles.
Show UV-LED irradiation time.
Show total number of chemical doses for fully
automated cleaning kit.
Show compressor run time (hrs).
Change model code.
23
drn
6000
0 hrs
100 hrs
hrs
(none)
res
res
res
err
ON
OFF
res
res
res
res
res
res
res
res
res
res
res

Hide quick links: