Rinnai REP199i Installation And Operation Manual page 25

Tankless water heater (with pump)
Hide thumbs Also See for REP199i:
Table of Contents

Advertisement

4.5.2 Termination
Considerations
Check to determine whether local codes
supersede the following clearances:
• Avoid termination locations near a dryer
vent.
• Avoid termination locations near
commercial cooking exhaust.
• You must install a vent termination at least
12 inches above the ground.
Important considerations for locating vent
termination under a soffit (ventilated or
unventilated or eave vent; or to a deck or porch)
• DO NOT install vent termination under a
vented soffit that may result in exhaust
gases entering the soffit vent.
• Install vent termination such that exhaust
and rising moisture will not collect under
eaves. Discoloration to the exterior of the
building could occur if installed too close.
• DO NOT install the vent termination too
close under the soffit where it could cause
recirculation of exhaust gases back into
the combustion air intake portion of the
termination.
12 in.
(0.30 m ) to
an inside
corner
Figure 16
Rinnai Tankless Water Heater Installation and Operation Manual
12 in.
(0.30 m) between
terminations at
same level
(1.52 m) vertically
between
terminations at
different levels
Figure 17
V
V
Figure 16
24 in.
(0.61 m) to wall or parapet
Figure 18
12 in.
Figure 19
60 in.
(1.52 m) vertically
60"
between
terminations
(0.30 m) between
terminations at
same level
25