To change the lamp:
1. If the unit has been running, switch the power to FAN
and wait 5 to 10 minutes for it to cool down.
2. Turn the power switch to OFF.
3. Press down on the door latch of the lamp module and
pull it slowly outward until the module clears the
projector.
4. Unclasp the wire bail which holds the lamp in place
and push from underneath the lamp to slide the lamp
out of the receptacle.
5. Reverse the procedure to insert the new lamp (make
sure that the new lamp is properly seated).
6. Lock the new lamp into place with the wire bail.