Dispensing agent connection to the liquid dispensing
mixing compartment
Connections 1 and 2 are provided for viscous agents. These
connections are sealed and need to be drilled open using an 8 mm
drill bit.
Connections 1 and 2 can also be used for high pressure dispensing
systems with water injection.
Important! The dispensing systems must comply with all relevant
local and national regulations.
Care must be taken to drill through the first wall (1) only, as there is a
deflecting wall (2) 10 mm behind it.
If the drilled out connections are no longer required, they must be
resealed.
Connections 3 to 12 are provided for liquid dispensing. These
connections are sealed and must be cut to suit the diameter of the
hose with a suitable hacksaw. If opened connections are no longer
required, they must be resealed.