HDSL T200 HTU-R, Span Powered, 60 mA Installation and Maintenance Practice
Indicator
ES 15M/24H
SES 15M/24H
UAS 15M/24H
1. LOSS is typically several dB less than the insertion loss measured at 200 kHz.
The LOSS measurement is a better indication of the loop's attenuation of the
2B1Q signal than the insertion loss measured at a single frequency. ADTRAN
HDSL can operate on cables with an excess of 30 dB LOSS.
2. The first number is for the current 15-minute period and the second is the cur-
rent 24-hour period (Loop 1 and Loop 2 numbers are displayed).
An indication of Pair Reversal (if present) appears at the bottom of the first key column. Definitions
for this key are provided in
DSX-1 signals is located in the center of the screen near the bottom.
Indicator
18

Table 10. HDSL, DS1, and DSX-1 Key Definitions

Definition
LOSS
Pulse attenuation measurement
SYNC
HDSL loop 1 and loop 2 sync status
Errored seconds
Severely errored seconds
Unavailable seconds
Table
11. Status and configuration information for the DS1 and

Table 11. Pair Reversal Key Definitions

Definition
FRAME
T1 framing format selected
CODE
T1 line coded selected
LBO
Line build-out selected (for DSX-1), Customer
signal of 0 or –15 dB (for DS1)
NIU
Network interface unit enabled
BPV
Bipolar violations detected (DSX-1 and DS1)
ES
Errored seconds (DSX-1 and DS1)
SES
Severely errored seconds (DSX-1 and DS1)
UAS
Unavailable seconds (DSX-1 and DS1)
Alarms
Lists current alarm condition status