Step 4 : Slightly shift up the Top Ornament Assembly as
shown.
Caution : Avoid touching the Remote Sensor during disas-
sembly of SMPS Unit.
Step 5 : Detach 2P wire at the connector (CN3) on the Line Fil-
ter P.C.B..
Step 6 : Detach 6P wire cable at the connector (CN100) on the
Main P.C.B..
Step 7 : Remove the SMPS Unit as arrow shown..
Caution : Ensure the 2P Wire and 6P Wire Cable are
dressed into grooves and guides as shown during assem-
bling of SMPS Unit.
38