Rheem Indirect Water Heater Instruction Manual page 4

Rheem mfg. co. indirect water heater instruction manual
Table of Contents

Advertisement

SECTION I: SPECIFICATIONS (cont .)
Table 2: Capacity & Performance
Model
STID30
30
STID40
38
STID50
45
STID80
75
STID120
110
NOTES:
* Based on 77°F rise with 58°F potable water inlet temperature at 8 GPM heat source flow rate. Heat source temperature was 180°F.
** Minimum Coil output based on continuous boiler operation over 30 minutes. See Section III for additional considerations.
All data obtained through testing in accordance with GAMA Indirect Water Heater-FIRED WATER HEATER TESTING STANDARD IWH-TS-1_MARCH 2003
Table 3: Performance (cont.)
Model
STID30
107 @ 53,000
STID40
141 @ 69,000
STID50
148 @ 69,000
STID80
188 @ 76,000
STID120
220 @ 76,000
NOTES:
First Hour Rating = First Draw + Continuous Draw
* Coil Input (temperature, flow rate). Ratings based on 77°F rise with 58°F inlet potable water.
All data obtained through testing in accordance with GAMA Indirect Water Heater -FIRED WATER HEATER TESTING STANDARD IWH-TS-1_MARCH 2003
Page 4
C a p a c i t i e s
1.38
110
2.30
153
2.30
160
2.76
200
2.76
232
FIRST HOUR RATING (gal) @ Coil Output (Btu/hr)
114 @ 57,000
117 @ 59,000
165 @ 84,000
177 @ 92,000
172 @ 84,000
184 @ 92,000
212 @ 91,000
224 @ 98,000
244 @ 91,000
256 @ 98,000
P e r f o r m a n c e
85
25
55,000
120
33
77,000
120
40
77,000
130
70
83,000
130
102
83,000
129 @ 67,000
132 @ 69,000
171 @ 88,000
183 @ 96,000
178 @ 88,000
190 @ 96,000
221 @ 97,000
233 @ 104,000
253 @ 97,000
265 @ 104,000
1.3
2.0
1.1
3.0
1.0
3.0
0.9
5.0
1.2
5.0
136 @ 71,000
139 @ 73,000
195 @ 104,000
207 @ 111,000
202 @ 104,000
214 @ 111,000
245 @ 112,000
257 @ 119,000
277 @ 112,000
289 @ 119,000

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents