Heater Resistance Checks
WARNING
ELECTROCUTION HAZARD
To reduce risk of injury or damage to
equipment, conduct these electrical
checks with the main disconnect OFF.
To check heater resistance:
1. Make sure the power is off and that the disconnect
switch is in the OFF position.
2. Make electrical resistance checks for the compo-
nents. Refer to Schematics on page 67 for wiring
diagram information.
3. Replace any parts whose resistance readings do
not comply with the ranges listed in the chart
below.
NOTE: Check resistance at ambient room tempera-
F).
ture (63_ – 77_
Installation
Heaters for 3-Zone Control Panels
Zone
1
2
3
Heaters for 4-Zone Control Panels
Zone
1
2
3
4
Component
Terminals
Follower
2L1 & 2L2
2L2 & 2L1
Dispense Hose
1532 &
1551
Dispense Gun
1602 &
1621
Component
Terminals
Follower
3L1 & 3L3
3L2 & 3L3
Dispense Gun
1532 &
1551
Dispense Hose
1602 &
1621
Pump
5L1 & 5L2
Value
Range
98 – 127
ohms
h
See
Technical
Data
supplied
w/Hose
See
Technical
Data
supplied
w/Gun
Value
Range
98 – 127
ohms
h
See
Technical
Data
supplied
w/Gun
See
Technical
Data
supplied
w/Hose
187.2 ohms
" 24 ohms
310528
17