Parameters, which are set up automatically

The following parameters
are tuned automatically.
Parameter No.
11
1st speed loop gain
12
1st speed loop integration time constant
13
1st speed detection filter
14
1st torque filter time constant
19
2nd speed loop gain
1A
2nd speed loop integration time constant
1B
2nd speed detection filter
1C
2nd torque filter time constant
20
Inertia ratio
Caution
[1] Immediately after the first servo ON at startup or when Pr22 (machine stiffness at real-time auto tuning)
is increased, abnormal noise or oscillation may be generated before load inertia is determined. This is
not anomaly if it is stabilized shortly. However when such problems as oscillation or noise that continues
for 3 reciprocal operations or longer is encountered frequently, take the following measures:
1) Write the parameter of normal operation into the EEPROM.
2) Decrease the Pr22 (Machine stiffness at real-time auto tuning).
3) Once set up Pr21 (Real-time auto tuning set-up) to 0 to disable the adaptive filter. Then, enable the
real time auto tuning again. (resetting of inertia estimate adaptive operation)
[2] After abnormal noise or oscillation, Pr20 (inertial ratio) may be changed to an extreme value. In such a
case, also take the above measures.
[3] Among results of real-time auto gain tuning, Pr20 (inertia ratio) is programmed into EEPROM every 30 min-
utes. When you turn on the power again, auto tuning will be executed using the data as initial value.
[Connections and Settings in Torque Control Mode]
Name
Parameter No.
The following parameters are also set up
to the following fixed values automatically.
Name
27
Disturbance torque observer filter selection
30
2nd gain action set-up
3A
Torque control switching mode
Set value
0
1
0
143