Miele SO Series Operating Instructions Manual page 10

Hide thumbs Also See for SO Series:
Table of Contents

Advertisement

Warning and Safety instructions
Temporary or permanent operation on an autonomous power sup-
ply system or a power supply system that is not synchronised with
the mains power supply (e.g. island networks, back-up systems) is
possible. A prerequisite for operation is that the power supply sys-
tem complies with the specifications of EN 50160 or an equivalent
standard.
The function and operation of the protective measures provided in
the domestic electrical installation and in this Miele product must
also be maintained in isolated operation or in operation that is not
synchronised with the mains power supply, or these measures must
be replaced by equivalent measures in the installation. As described,
for example, in the current version of BS OHSAS 18001–2 ISO
45001.
Charge and use the battery at an ambient temperature between
0 °C and 45 °C.
Using the battery outside of this ambient temperature range will limit
its performance.
Only the LG01/xx or LG02/xx charger supplied or the LS03/xx
charger cradle supplied or purchased as an optional accessory
should be used to charge the AP01/AP02/AP03 battery.
xx stands for 01, 02, 03, 04, 05, 06, 07 or 08; these numbers identify
the version of your LG01/LG02 charger and your LS03 char-
ger cradle.
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Triflex hx1Hs19

Table of Contents