NEC Express 5800/320Lc User Manual page 304

Nec server user's guide
Table of Contents

Advertisement

7-36
Troubleshooting
EvntAgnt log is recorded in the application event log:
→ This event does not have any influence on the system, not on SNMP services.
Thus no measurement is required.
Source:
ID:
Description: TraceFileName parameter not located in registry; Default trace file
Source:
ID:
Description: TraceLevel parameter not located in registry; Default trace level
SCSI control error appears in the system event log:
→ There is sometimes a case that SCSI control error that has a source of sraq160
appears in the system event log. This symptom occurs when the processing speed
of HDDs is slower than the request from the operating system, and the process
will be continued properly by the retry function. Since this does not affect any
operations, check the detailed data as described below and ignore that log if the
data is either "f0030004" or "f0030015".
However, if the SCSI control error in the detailed data above repeatedly shows
either "f0030004" or "f0030015" (more than 10 times a week as an indication),
the HDD failure can be occurring. Contact your maintenance service company.
The srabid error log is recorded in the system event log at system startup:
→ The following log may be recorded in the system event log at system startup, but
there is no problem for operation.
Source:
Type:
ID:
Description: CPU board dump harvest failed.
Source:
Type:
ID:
Description: CPU board dump harvest failed.
EvntAgnt
1003
used is .
EvntAgnt
1015
used is 32.
srabid
Error
300
Status from Common Code: ErrDumpDoesntExist (0x8123).
srabid
Error
300
Status from Common Code: ErrMagic (0x8188).

Advertisement

Table of Contents
loading

Table of Contents