Appendix
Caution
To comply with GR-1089 intrabuilding, lightning immunity requirements, you must use a foil twisted-pair
(FTP) cable that is properly grounded at both ends.
The following figure shows the RJ-45 connector.
Figure 22: RJ-45 Connector
Transceiver and Cable Specifications
To determine which transceivers and cables are supported by this router, see
Compatibility
To see the transceiver specifications and installation information, see
Upgrade
RJ-45 ToD or 1-PPS Port Pinouts
This summarizes the RJ-45 ToD or 1-PPS port pinouts:
Table 9: RJ-45 ToD or 1-PPS Port Pinouts
Pin
1
2
3
4
5
6
7
8
Cisco Network Convergence System 540 Passive Cooled Small Density Routers Hardware Installation Guide
Information.
Guides.
Signal Name
NA
NA
1PPS_N
GND
GND
1PPS_P
TOD_N
TOD_P
Transceiver and Cable Specifications
Cisco Transceiver Modules
Cisco Transceiver Modules Install and
Direction
Description
NA
NA
NA
NA
Output or Input
1PPS RS422 signal
NA
NA
NA
NA
Output or Input
1PPS RS422 signal
Output or Input
Time-of-Day character
Output or Input
Time-of-Day character
49